An Internet survey demonstrated the existence of problems related to intraoperative tracking camera set-up and alignment. It is hypothesized that these problems are a result of the limited field of view of today's optoelectronic camera systems, which is usually insufficiently large to keep the entire site of surgical action in view during an intervention. A method is proposed to augment a camera's field of view by actively controlling camera orientation, enabling it to track instruments as they are used intraoperatively. In an experimental study, an increase of almost 300% was found in the effective volume in which instruments could be tracked.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3109/10929080500483473 | DOI Listing |
Neurosurg Rev
January 2025
Department of Neurosurgery, Sana Kliniken Duisburg, Academic Teaching Hospital of University Duisburg-Essen, Duisburg, Germany.
Pineal gland lesions pose a significant surgical challenge due to the deep-seated nature of the pineal gland, as well as the limited field of view, and the complex vascular anatomy. The mainstay of surgical treatment, when necessary, is always histopathological clarity and gross total resection (GTR). We evaluate the surgical outcomes for pineal gland lesions, shedding light on functional outcomes, histological findings, and surgical complications.
View Article and Find Full Text PDFEur J Nucl Med Mol Imaging
January 2025
Nuclear Medicine and Clinical Molecular Imaging, University Hospital Tuebingen, Otfried-Mueller-Str. 14, 72076, Tuebingen, Germany.
Purpose: Somatostatin receptor (SSTR)-PET is crucial for effective treatment stratification of neuroendocrine neoplasms (NENs). In highly proliferating or poorly differentiated NENs, dual-tracer approaches using additional [F]FDG PET can effectively identify SSTR-negative disease, usually requiring separate imaging sessions. We evaluated the feasibility of a one-day dual-tracer imaging protocol with a low activity [F]FDG PET followed by an SSTR-PET using the recently introduced [F]SiFAlin-TATE tracer in a long axial field-of-view (LAFOV) PET/CT scanner and its implications in patient management.
View Article and Find Full Text PDFAcc Mater Res
January 2025
School of Chemical & Biomolecular Engineering, Georgia Institute of Technology, Atlanta, Georgia 30322, United States.
Increasing demand for high-purity fine chemicals and a drive for process intensification of large-scale separations have driven significant work on the development of highly engineered porous materials with promise for sorption-based separations. While sorptive separations in porous materials offer energy-efficient alternatives to longstanding thermal-based methods, the particulate nature of many of these sorbents has sometimes limited their large-scale deployment in high-throughput applications such as gas separations, for which the necessary high feed flow rates and gas velocities accrue prohibitive operational costs. These processability limitations have been historically addressed through powder shaping methods aimed at the fabrication of structured sorbent contactors based on pellets, beads or monoliths, commonly obtained as extrudates.
View Article and Find Full Text PDFJ Econ Methodol
December 2024
Institute of Philosophy, Leibniz University Hannover, Hannover, Germany.
Methodological appraisal usually aims at a discourse that contributes to the improvement of knowledge production processes in economics. Attempts by economists, such as that by Gilboa et al. (2022.
View Article and Find Full Text PDFCancer Imaging
January 2025
Melbourne Theranostic Innovation Centre, Level 8, 14-20 Blackwood St, North Melbourne, VIC, 3051, Australia.
True total-body and extended axial field-of-view (AFOV) PET/CT with 1m or more of body coverage are now commercially available and dramatically increase system sensitivity over conventional AFOV PET/CT. The Siemens Biograph Vision Quadra (Quadra), with an AFOV of 106cm, potentially allows use of significantly lower administered radiopharmaceuticals as well as reduced scan times. The aim of this study was to optimise acquisition protocols for routine clinical imaging with FDG on the Quadra the prioritisation of reduced activity given physical infrastructure constraints in our facility.