Acephate is a commonly used organophosphate insecticide applied on agricultural crops and in residential communities. Because very little acephate is metabolized prior to excretion, the parent pesticide compound can be measured in human urine. The residue method must be sensitive enough to determine human exposure and potential health risk for both agricultural workers and their families who may be exposed by pesticide drift or by inadvertent carry-home residues. A reliable and sensitive method was developed to measure acephate concentrations in human urine. Urine was diluted with water and acetone, adjusted to a neutral pH, and partitioned twice in acetone-methylene chloride (1 + 1, v/v), with NaCl added to aid separation. The solvent-reduced organic phase extracts were clarified by activated charcoal solid-phase extraction and then adjusted to a final volume with the addition of a D-xylose analyte protectant solution to reduce matrix enhancement effects. Acephate concentrations in urine were determined by gas chromatography using pulsed flame photometric detection. The method limit of detection was established at 2 microg/L, with a method limit of quantitation of 10 microg/L. The average recovery from urine fortified with 10-500 microg/L was 102 +/- 12% (n = 32).
Download full-text PDF |
Source |
---|
BMC Womens Health
January 2025
Postgraduate Program in Medicine and Human Health, Bahiana School of Medicine and Public Health, Rua Silveira Martins, nº 3386, Cabula, Salvador, BA, 41150-000, Brazil.
Introduction And Hypothesis: Urinary incontinence (UI) is defined as any involuntary loss of urine and can be associated with urgency and/or physical exertion. Electrical stimulation (ES) has recently been identified as a proven therapeutic alternative for UI, with few side effects and low cost. This systematic review, registered on the Prospective Register of Systematic Reviews (RD42024528812), investigated whether home-based ES would be as viable as outpatient ES in the treatment of women with UI.
View Article and Find Full Text PDFDrug Metab Dispos
January 2025
Drug Metabolism and Toxicology, Faculty of Pharmaceutical Sciences, Kanazawa University, Kakuma-machi, Kanazawa, Japan; WPI Nano Life Science Institute (WPI-NanoLSI), Kanazawa University, Kakuma-machi, Kanazawa, Japan.
Pirfenidone (PIR) is used in the treatment of idiopathic pulmonary fibrosis. After oral administration, it is metabolized by cytochrome P450 1A2 to 5-hydroxylpirfenidone (5-OH PIR) and further oxidized to 5-carboxylpirfenidone (5-COOH PIR), a major metabolite excreted in the urine (90% of the dose). This study aimed to identify enzymes that catalyze the formation of 5-COOH PIR from 5-OH PIR in the human liver.
View Article and Find Full Text PDFNefrologia (Engl Ed)
January 2025
Division of Nephrology IIS-Fundacion Jimenez Diaz, Department of Medicine, Universidad Autónoma de Madrid, Madrid, Spain; RICORS2040, Carlos III Institute of Health, Madrid, Spain.
Introduction: Chronic kidney disease (CKD) is associated with high cardiovascular disease (CVD) risk, and requires specific interventions to decreases CVD risk. The guidelines indicate that systematic global CVD risk assessment is recommended in individuals with any major vascular risk factor. The European Society Cardiology (ESC) guidelines, he European Renal Association (ERA) Council and the Spanish Society of Nephrology (S.
View Article and Find Full Text PDFJ Glob Antimicrob Resist
January 2025
Department of Clinical Microbiology, Rigshospitalet, Copenhagen, Denmark.
Background: Staphylococcus saprophyticus is the second most common bacteria causing uncomplicated urinary tract infections (UTI). It is considered non-susceptible to mecillinam, with no defined breakpoint and only few available minimal inhibitory concentration (MIC) observations. However, this consideration does not correlate with clinical outcome.
View Article and Find Full Text PDFSci Rep
January 2025
Praxis Dr.Carmine, Etzelstrasse 21, Pfaeffikon SZ, 8808, Switzerland.
Spot-urinary biomarkers are crucial in medical, epidemiological, and environmental studies, but their variability due to hydration levels requires precise dilution adjustments. Traditional methods, like conventional creatinine correction (CCRC), are limited in compensating for variations in urine concentration, causing substantial inconsistencies, particularly at the extremes of the diuresis spectrum. While restricting the creatinine (CRN) range to 0.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!