Short-wavelength-sensitive (SWS) resolution acuity has been reported to be limited by the density of the responding ganglion cells for people without appreciable age-related lenticular change. This study measured the robustness of SWS-cone acuity and contrast sensitivity (CS) to simulated lens yellowing and opacification. Resolution acuity at 8 deg eccentricity proved robust to significant amounts of yellowing and remained lower than detection acuity, indicating that the resolution continued to be limited by ganglion cell density. Both the detection and resolution CS functions were affected by simulated lens yellowing, except for resolution close to the CS cut-off. For simulated opacification, only dense opacity significantly affected performance. SWS resolution acuity and CS close to the resolution limit are resistant to moderate simulated age-related lens changes and continue to be mediated by the density of the responding ganglion cells, indicating important clinical potential to measure SWS neural losses of vision in older subjects.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.visres.2006.01.025DOI Listing

Publication Analysis

Top Keywords

simulated lens
12
lens yellowing
12
resolution acuity
12
yellowing opacification
8
acuity contrast
8
contrast sensitivity
8
sws resolution
8
density responding
8
responding ganglion
8
ganglion cells
8

Similar Publications

Single-shot 3D optical microscopy that can capture high-resolution information over a large volume has broad applications in biology. Existing 3D imaging methods using point-spread-function (PSF) engineering often have limited depth of field (DOF) or require custom and often complex design of phase masks. We propose a new, to the best of our knowledge, PSF approach that is easy to implement and offers a large DOF.

View Article and Find Full Text PDF

Light manipulation and control are essential in various contemporary technologies, and as these technologies evolve, the demand for miniaturized optical components increases. Planar-lens technologies, such as metasurfaces and diffractive optical elements, have gained attention in recent years for their potential to dramatically reduce the thickness of traditional refractive optical systems. However, their fabrication, particularly for visible wavelengths, involves complex and costly processes, such as high-resolution lithography and dry-etching, which has limited their availability.

View Article and Find Full Text PDF

Refractive error maps: A predictive tool for refractive error progression.

Ophthalmic Physiol Opt

January 2025

Faculty of Health, Medicine and Social Care, Medical Technology Research Centre, Anglia Ruskin University, Chelmsford, UK.

Purpose: To investigate the influence of axial length on different ocular parameters and create a predictive tool for refractive error progression.

Methods: Two eye models were used to simulate refractive errors, namely the Liou-Brennan and the Goncharov-Dainty. Both models were simulated using Zemax OpticStudio.

View Article and Find Full Text PDF

Aim: To report the clinical and therapeutic particularities of pediatric keratoconus (KC).

Methods: Retrospective study focusing on patients aged less than 18 years, presenting with KC and followed in a tertiary reference center in Sfax, Tunisia.

Results: Our study involved 38 eyes of 20 children.

View Article and Find Full Text PDF

In human eye, structural proteins, known as crystallins, play a crucial role in maintaining the eye's refractive index. These crystallins constitute majority of the total soluble proteins found in the eye lens. Among them, α-crystallins (α-CR) is one of the major components.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!