Environmental variations in patient-dependent and surgical factors were modeled using robust optimization with a finite element acetabular cup-pelvis model. A previously developed statistical optimization scheme was used to: (1) determine the cup geometry and the optimal cup-bone interference that maximized bone-implant contact areas and minimized changes in the gap volume between the implant and bone surface during gait loading and unloading; and (2) determine the relative contributions of design, patient-dependent, and surgical factors to variations in bone-implant contact areas and a change in gap volume. The statistical analyses indicated that the design variables, namely the equatorial diameter and eccentricity, explained most of the variations in the performance measures. Further, the hemispherical designs performed better than the nonhemispherical designs. The 58 mm hemispherical cup, with 2 mm diametral interferences, minimized the change in gap volume and attained 82% and 81% of the maximum predicted total and rim contact areas, respectively. The equatorial diameter and eccentricity, not the patient-dependent and surgical factors, explained most of the variations in the performance measures. Perfect surface apposition was not attained with any of the cup designs.

Download full-text PDF

Source
http://dx.doi.org/10.1115/1.2165701DOI Listing

Publication Analysis

Top Keywords

patient-dependent surgical
12
surgical factors
12
contact areas
12
gap volume
12
cup geometry
8
bone-implant contact
8
change gap
8
equatorial diameter
8
diameter eccentricity
8
explained variations
8

Similar Publications

Introduction: Femoral neck fractures in young adults, particularly Pauwels' 3 fractures with angles exceeding 70°, pose challenges in determining optimal surgical interventions due to limited clinical trial data. Complications such as avascular necrosis, non-union, and shortening hinder the healing process. Existing fixation methods, including multiple cannulated screws and sliding hip screws, have shown non-union rates of nearly 9% in young patients.

View Article and Find Full Text PDF

Rectal stenosis after circular mechanical anastomosis; the influence of stapler size.

Surg Endosc

December 2024

Coloproctology Unit, General and Digestive Surgery Service, Parc Tauli University Hospital, Sabadell. Institut d'investigació i innovació Parc Tauli I3PT-CERCA, Sabadell (Barcelona), Spain.

Background: The incidence of benign anastomotic stenosis (BAS) after radical surgery for rectal cancer ranges from 2 to 30%. There are few data regarding the factors related to its occurrence. One of these factors is the diameter of the circular mechanical staplers (CMS) used.

View Article and Find Full Text PDF

LatticeOpt: An automatic tool for planning optimisation of spatially fractionated stereotactic body radiotherapy.

Phys Med

October 2024

Azienda USL-IRCCS di Reggio Emilia, Medical Physics Unit, Department of Advanced Technology, Reggio Emilia, Italy.

Purpose: Lattice radiotherapy (LRT) is a three dimensional (3D) implementation of spatially fractionated radiation therapy, based on regular spatial distribution of high dose spheres (vertices) inside the target. Due to tumour shape heterogeneity, finding the best lattice arrangement is not trivial. The aim of this study was to develop the LatticeOpt tool to generate the best lattice structures on clinical cases for treatment planning.

View Article and Find Full Text PDF

Background: This study evaluates the long-term stability and clinical outcomes of the reverse palatal pedicle graft (RPPG) technique in treating maxillary molar palatal recessions over a 3 to 4-year follow-up period.

Methods: Three patients with palatal recession defects on maxillary molars were treated using the RPPG technique. Clinical parameters including recession depth, probing depth, and clinical attachment levels (CALs) were recorded at baseline, 2 months, and 3-4 years postoperatively.

View Article and Find Full Text PDF

Background: Enhanced recovery after surgery (ERAS) is a perioperative care protocol, which was introduced several years ago and has gained increasing importance in thoracic surgery. The aim of this study was to provide guidance through clinical implementation and to identify factors for better compliance.

Methods: This prospective cohort study collected data between July 2021 and June 2022 at the Department of Thoracic Surgery (University Hospital Regensburg, Germany).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!