A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Permeability of 13 different gloves to 13 cytotoxic agents under controlled dynamic conditions. | LitMetric

Permeability of 13 different gloves to 13 cytotoxic agents under controlled dynamic conditions.

Am J Health Syst Pharm

Clinical Chemistry Department, University Hospital St. Luc, Université Catholique de Louvain, 10 Hippocrate Avenue, B-1200 Brussels, Belgium.

Published: March 2006

Purpose: The permeability of 13 different gloves to 13 cytotoxic agents under controlled dynamic conditions is described.

Methods: Thirteen cytotoxic agents were prepared at the highest concentrations normally encountered by pharmacy personnel. Four glove types--neoprene, natural rubber latex, nitrile, and vinyl--were exposed to the cytotoxic agents for 15, 30, and 60 minutes. Tests were conducted using the middle finger of each glove. Linearity, reproducibility, and sensitivity were evaluated for each drug tested. Assays were run using liquid chromatographic tandem mass spectrometry (LC/MS/MS) and high-performance liquid chromatography with ultraviolet light (HPLC-UV). Permeability testing was conducted using an original system designed to evaluate dynamic constraints, such as rubbing, stretching, and tension.

Results: Linearity by LC/MS/MS and HPLC-UV was confirmed at concentrations up to 1000 ng/mL for all drugs. Most glove materials were permeable at rates below ASTM recommendations over the one-hour testing period. Vinyl was the most permeable material. Carmustine permeated the widest variety of materials. Due to the high sensitivity of the analytic methods, all materials displayed low but significant permeability for at least one drug after one hour. Higher resistance to permeation was recorded for all neoprene, some natural rubber latex, and one nitrile glove.

Conclusion: Neoprene, natural rubber latex, and nitrile gloves displayed the highest resistance to permeation of the 13 cytotoxic agents studied. Additional factors, such as duration of exposure, glove thickness, and drug liposolubility and molecular weight, also affected permeability.

Download full-text PDF

Source
http://dx.doi.org/10.2146/ajhp050197DOI Listing

Publication Analysis

Top Keywords

cytotoxic agents
20
natural rubber
12
rubber latex
12
latex nitrile
12
permeability gloves
8
gloves cytotoxic
8
agents controlled
8
controlled dynamic
8
dynamic conditions
8
resistance permeation
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!