In vivo ovum pick-up (OPU) in sheep may be improved with a proper choice of aspiration elements (needle and tubing) and aspiration vacuum pressure. In the present study, two experiments were carried out. In Expt 1, visible follicles in ovaries of slaughtered ewes (treated separately according to their diameters: small<3 mm, medium 3-5 mm and large>5 mm) were aspirated using different combinations of the three studied factors such as aspiration flow rate (10, 20, 30, 40 and 50 ml water/min), needle gauge (18 and 20 G) and tubing inner diameter (1, 2 or 3 mm internal diameter). In Expt 2, a study with two 18 G needles of different lengths (18 G: 82 mm; 18 GL: 600 mm) was carried out, using ovaries obtained post-mortem, and performing in vivo laparoscopic follicular aspiration on ewes. We considered good quality oocytes as those with both complete compact cumulus and a homogeneous cytoplasm. Recovery rate, proportion of good quality oocytes (good quality oocytes/100 oocytes recovered) and overall efficiency (good quality oocytes/100 follicles aspirated) were noted. In Expt 1, aspiration flow rate affect remarkable proportion of good quality oocytes (69.5%, 50.5%, 44.8%, 36.5% and 28.3% for flows from 10 to 50 ml/min respectively, p<0.05). Needle gauge did not affect aspiration device efficiency. Thin and intermediate tubings were more effective (overall efficiency rates: 34.9%, 32.3% and 28.1% for 1, 2 and 3 mm respectively, p<0.05). Follicle size did not affect recovery rate, but proportion of good quality oocytes was higher for large (77.9%) and medium (64.4%) follicles (p<0.05). Finally, some combinations of the aspiration device showed greater effectiveness. In Expt 2, needle length did not influence recovery rate, but good quality oocytes rate was significantly modified both post-mortem and in vivo (good quality rate for 18 G vs 18 GL needles: 69.5% vs 47.7% and 58.1% vs 25.4%, post-mortem and in vivo respectively, p<0.05). We conclude that low-aspiration flow rates (10 and 20 ml/min) with thin or intermediate tubings (1 and 2 mm), and any short needle (18 G or 20 G) are the most adequate aspiration factors for OPU in sheep.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1439-0531.2006.00648.x | DOI Listing |
Biomed Phys Eng Express
January 2025
Advanced Nuclear Medicine Science, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555, JAPAN, Chiba, 263-8555, JAPAN.
For brain-dedicated positron emission tomography (PET) scanners, depth-of-interaction (DOI) information is essential to achieve uniform spatial resolution across the field-of-view (FOV) by minimizing parallax error. Time-of-flight (TOF) information can enhance the image quality. In this study, we proposed a novel monolithic U-shaped crystal design that had a tapered geometry to achieve good coincidence timing resolution (CTR) and DOI resolution simultaneously.
View Article and Find Full Text PDFPLoS One
January 2025
Faculty of Medicine, Division of Population Health and Applied Health Sciences, Clinical Epidemiology Unit, Memorial University, St. John's, Newfoundland and Labrador, Canada.
Background: The number of persons living with multimorbidity-defined as the co-occurrence of at least two chronic conditions in the same individual-is growing globally, especially in developed countries. Traditionally, this increase has been attributed to a growing aging population, sedentary lifestyle, obesity, low socioeconomic status, and individual genetic susceptibility.
Objective: To investigate the prevalence and associated risk factors of the most common multimorbidity (MCM) among Canadian middle-aged and older adults.
Invest Radiol
January 2025
From the Department of Neuroradiology, University Medical Center Mainz, Johannes Gutenberg University, Mainz, Germany (L.S.L., K.H.H., A.K., M.A.B., S.A., A.E.O.); Institute of Medical Biostatistics, Epidemiology, and Informatics, University Medical Center Mainz, Johannes Gutenberg University, Mainz, Germany (R.H.P.); and Siemens Healthineers AG, Forchheim, Germany (D.P., D.N.S.).
Objectives: The aim of this study was to investigate the occurrence of motion artifacts and image quality of brain magnetic resonance imaging (MRI) T1-weighted imaging applying 3D motion correction via the Scout Accelerated Motion Estimation and Reduction (SAMER) framework compared with conventional T1-weighted imaging at 1.5 T.
Materials And Methods: A preliminary study involving 14 healthy volunteers assessed the impact of the SAMER framework on induced motion during 3 T MRI scans.
JMIR Serious Games
January 2025
Department of Industrial Design, National Cheng Kung University, Tainan, Taiwan.
Background: Aging in older adults results in a decline in physical function and quality of daily life. Due to the COVID-19 pandemic, the exercise frequency among older adults decreased, further contributing to frailty. Traditional rehabilitation using repetitive movements tends not to attract older adults to perform independently.
View Article and Find Full Text PDFAbdom Radiol (NY)
January 2025
The General Hospital of Western Theater Command, Chengdu, Sichuan 610083, China, Chengdu, China.
Background: Perineural invasion (PNI) in colorectal cancer (CRC) is a significant prognostic factor associated with poor outcomes. Radiomics, which involves extracting quantitative features from medical imaging, has emerged as a potential tool for predicting PNI. This systematic review and meta-analysis aimed to evaluate the diagnostic accuracy of radiomics models in predicting PNI in CRC.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!