A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Measuring human complement activation by HLA antibodies. | LitMetric

Measuring human complement activation by HLA antibodies.

Arch Pathol Lab Med

Department of Pathology, University of Florida College of Medicine, Gainesville, FL 32608, USA.

Published: March 2006

Context: The clinical significance of HLA antibodies in transplantation depends on their ability to activate complement, which is measured by the standard complement-dependent cytotoxicity test. Recent reports indicate that C3b measurement on target cells may be a better indicator of human complement activation than standard cytotoxicity.

Objective: To determine the characteristics of the test, the role of other complement components, and the potential influence of the patient's own complement activity.

Design: The T-cell deposition of multiple complement components triggered by HLA alloantibodies was evaluated by flow cytometry using normal human serum as the source of complement. Complement activity in patients' sera was measured after activation with a standard antibody.

Results: When HLA antibodies activate complement, C3b deposition is usually highest, followed by that of C4b and C5b. Deposition of C1q, C3d, iC3b, or C5b-9 was low or undetectable in this study. The C5 was activated only when relatively high levels of C3b were present. There was a critical concentration of antibody, unique for each patient, below which activation of C3 declined abruptly. The complement activity in the serum of candidates for liver, heart, and lung transplantation that was tested with a standard antibody was similar to normal serum. In contrast, kidney transplant candidates exhibited higher complement activity. Unexpectedly, serum C3 activity was retained for at least 72 hours after collection.

Conclusions: Measurement of C3b, and in some instances C4b or C5b, offers a better definition of the ability of HLA antibodies to activate human complement than tests that are in current use. The results provide a necessary baseline to conduct clinical correlation studies.

Download full-text PDF

Source
http://dx.doi.org/10.5858/2006-130-368-MHCABHDOI Listing

Publication Analysis

Top Keywords

hla antibodies
16
complement
12
human complement
12
complement activity
12
complement activation
8
activate complement
8
activation standard
8
complement components
8
antibodies activate
8
c4b c5b
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!