Electroretinography is commonly used to assess the functional integrity of the retina. There are many external variables that can influence the electroretinographic waveforms recorded, and it is important to be aware of these so as not to misinterpret their effects as abnormalities in retinal function. In this study we examined the effect of three different recording electrodes on the ERGs recorded from normal dogs. A bipolar Burian-Allen lens, a monopolar Dawson Trick Litzkow (DTL) fiber electrode, and a monopolar ERG-Jet lens electrode were compared. The effect of altering the distance of the reference electrode from the eye was also examined; using the ERG-Jet lens electrode, the ERG was recorded with the reference electrode placed over the zygomatic arch at 1, 3 and 5 cm caudal to the lateral canthus. The ERGs recorded with the bipolar Burian-Allen lens had significantly lower amplitudes, higher a-wave thresholds and a shallower initial a-wave slope, than those recorded by the two monopolar electrodes. Positioning the reference electrode further from the eye resulted in significantly higher amplitudes. Naka-Rushton fitting and calculation of retinal sensitivity (K) gave significantly different results between the Burian-Allen lens and ERG-Jet lens electrode with the reference electrode 5 cm from the lateral canthus. These results demonstrate that recording electrode type and distance of the reference electrode from the eye significantly affect the ERG tracings of the dog, and may alter the assessment of retinal function that can therefore be derived. Results obtained using these three different types of electrodes cannot be directly compared.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10633-005-4517-7 | DOI Listing |
PLoS One
January 2025
National Heart and Lung Institute, Imperial College London, London, United Kingdom.
Introduction: Haemodynamic atrioventricular delay (AVD) optimisation has primarily focussed on signals that are not easy to acquire from a pacing system itself, such as invasive left ventricular catheterisation or arterial blood pressure (ABP). In this study, standard clinical central venous pressure (CVP) signals are tested as a potential alternative.
Methods: Sixteen patients with a temporary pacemaker after cardiac surgery were studied.
RSC Adv
January 2025
Nano-Science Center & Department of Chemistry, University of Copenhagen Universitetsparken 5 2100 København Ø Denmark
pH remains the most important chemical parameter and must be monitored for positive outcomes in areas as different as cheese making and fertilisation (IVF). Where blood gas analysers enable patient monitoring, starter cultures in cheese manufacturing are still monitored using conventional pH electrodes. Here, we present a homogeneous multiwell plate sensor for monitoring pH, with the same sensitivity as a pH electrode.
View Article and Find Full Text PDFNpj Ment Health Res
January 2025
Clinical Research Center for Mental Disorders, Shanghai Pudong New Area Mental Health Center, School of Medicine, Tongji University, Shanghai, 200124, China.
This meta-analysis investigated resting frontal alpha asymmetry (FAA) as a potential biomarker for major depressive disorder (MDD). Studies included articles utilizing FAA measure involving EEG electrodes (F3/F4, F7/F8, or Fp1/Fp2) and covering both MDD and controls. Hedges' d was calculated from FAA means and standard deviations (SDs).
View Article and Find Full Text PDFJ Neurophysiol
January 2025
Department of Health and Exercise Science, University of Oklahoma, Norman, OK, USA.
Transcutaneous spinal direct current stimulation (TSDCS) has the potential to modulate spinal circuits and induce functional changes in humans. Nevertheless, differences across studies on basic parameters used and obtained metrics represent a confounding factor. Computer simulations are instrumental in improving the application of the TSDCS technique.
View Article and Find Full Text PDFJACC Clin Electrophysiol
December 2024
The Hull Family Cardiac Fibrillation Management Laboratory, Toronto General Hospital, University Health Network, Toronto, Ontario, Canada.
Background: Conduction velocity (CV) is a measure of the health of myocardial tissue. It can be measured by taking differences in local activation times from intracardiac electrodes. Several factors introduce error into the measurement, among which ignoring the 3-dimensional aspect is a major detriment.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!