A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

An improved technique for gaining radial artery access in endovascular interventions. | LitMetric

We present a simple technique to avoid time loss and potential dangerous maneuvers for catheterization of the radial artery in endovascular interventions. If any difficulties are encountered when advancing the guide wire after the arterial puncture using standard transradial kits, we found it useful to routinely use a 60-mm polyethylene radial pressure line catheter like the Leader Cath (Vygon, Ecquen, France), which is more flexible and less traumatic than short catheters and are usually available in the standard hydrophilic transradial kit. With the 20-gauge needle within the arterial lumen, it is sufficient to advance the guide wire 3 or 4 cm, followed by the insertion of the radial pressure line catheter for administering a vasodilator cocktail. The contrast injection through the catheter is safer than through the needle, and visualization of the underling problems may avoid any time loss and complications. The standard sheath insertion is facilitated by the pressure line catheter that acts as a dilator. This technique, especially when performing coronary or peripheral interventions in which large introducers are needed, may avoid potentially dangerous vascular complications and improve the success rate.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.carrev.2005.11.001DOI Listing

Publication Analysis

Top Keywords

pressure catheter
12
radial artery
8
endovascular interventions
8
avoid time
8
time loss
8
guide wire
8
radial pressure
8
improved technique
4
technique gaining
4
radial
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!