Background: Sentinel node biopsy (SNB) for breast cancer has a false-negative rate of approximately 5%. Initial reports of follow-up show lower axillary recurrence rates than expected. We performed axillary ultrasonography to determine whether occult recurrences could be detected.
Methods: In a community hospital setting, 289 patients who had SNB for breast cancer in a single surgeon's practice underwent axillary examination by the surgeon followed by axillary ultrasonography by a dedicated breast radiologist. Ultrasonography was performed one time from 4 to 79 months (median, 25 months) after surgery. Five patients with suspicious nodes had ultrasound-guided fine-needle aspiration, and one had a core biopsy.
Results: No patient had suspicious nodes on clinical examination. Only six patients had ultrasound findings that warranted intervention. Five patients had benign cytological characteristics, and one had a benign core biopsy result. No evidence of axillary recurrence was found in any patient.
Conclusions: Axillary ultrasonography did not detect occult metastases in any patient and is not recommended for routine follow-up after SNB. The lack of ultrasound evidence of metastasis suggests that the recurrence rate is likely to remain low.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1245/ASO.2006.05.015 | DOI Listing |
Front Immunol
January 2025
Department of Rheumatology and Clinical Immunology, Clinic of Internal Medicine III, University Hospital Bonn, Bonn, Germany.
Objectives: This study aimed to evaluate the diagnostic utility of [Ga]Ga-DOTA-Siglec-9 positron emission tomography-computed tomography (PET/CT) in assessing disease activity in a patient experiencing a relapse of giant cell arteritis (GCA).
Case Presentation: A 90-year-old male patient with GCA, diagnosed in 2018, was enrolled. Demographic data, disease history, and laboratory parameters, including soluble VAP-1 (sVAP-1) levels, were recorded.
Clin Radiol
December 2024
Royal Liverpool University Hospital, Breast Radiology Unit, Liverpool, UK.
Aim: This study aimed to detail our experience of using SCOUT® radar reflector for lesion localisation in the breast and axilla.
Materials And Methods: This is a prospective cohort study describing our clinical experience with the first 500 patients who received SCOUT® to localise lesions in the breast and axilla (from 23 July 2020 to 4 April 2022). Study measures include patient demographics, lesion location, diagnostic pathways (screening or symptomatic), imaging, and surgical and pathology outcomes.
J Cardiothorac Surg
January 2025
Department of Cardiovascular Surgery, Sapporo Cardio Vascular Clinic, 8-1, Kita 49 jyo, Higashi 16 jyo, Higashi-ku, Sapporo, Hokkaido, 007-0849, Japan.
Background: Minimally invasive cardiac surgery for mitral regurgitation is challenging in patients with narrow chests due to limited thoracic space. The butterfly technique can prevent systolic anterior motion in patients with degenerative mitral regurgitation and redundant posterior leaflets, but it is difficult to perform via minimally invasive cardiac surgery. Few reports have described mitral valve repair using the butterfly technique or in a narrow chest.
View Article and Find Full Text PDFJ Med Case Rep
January 2025
Department of Pathology and Laboratories, University Hospital Fundación Santa Fe de Bogotá, Bogotá, DC, Colombia.
Background: Adenoid cystic carcinoma of the breast is a rare subtype, constituting less than 3.5% of primary breast carcinomas. Despite being categorized as a type of triple-negative breast cancer, it generally has a favorable prognosis.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Medical Pathology, Ege University Faculty of Medicine, Ege University Hospital, Bornova, İzmir, Turkey.
This study aimed to evaluate the diagnostic accuracy of ultrasonography in assessing the response of clipped axillary lymph nodes to neoadjuvant chemotherapy. Between February 2022 and September 2023, 43 patients who underwent axillary lymph node marking for targeted axillary dissection were retrospectively analyzed. Ultrasonography parameters such as the number, size, shape, cortical thickness, hilum status, and treatment response of the clipped lymph node were assessed.