Object: In this study the authors evaluated levels of radiation exposure to surgeons' protected and unprotected hands during fluoroscopically assisted vertebroplasty.
Methods: The amount of radiation administered to 30 patients during 41 procedures in a controlled prospective trial over 6 months was assessed, comparing radiation exposure to the right and left hands in two neurosurgeons. Effective skin doses were evaluated using thermoluminescent finger dosimeters (ring dosimeters). The ratios of finger dosimeter exposure were compared between the glove-protected and unprotected left hands of two surgeons and both unprotected right hands. In addition, dose-area product (DAP) and fluoroscopy times were recorded in all patients. The mean treatment-effective dose to the surgeons' hands was 0.49 +/- 0.4 mSv in the glove-protected left hand and 1.81 +/- 1.31 mSv in the unprotected left hand (p < 0.05). The mean effective hand doses were 0.59 +/- 0.55 mSv in the unprotected right hand of the glove-protected surgeon and 0.62 +/- 0.55 mSv in the unprotected right hand of the control surgeon. The total corresponding fluoroscopy time was 38.55 minutes for the protected surgeon and 41.23 minutes for the unprotected one (p > 0.05). Lead glove shielding resulted in a radiation dose reduction of 75%. The total DAP for all procedures was 256,496 mGy/cm2 and 221,408 mGy/cm2 (p > 0.05) for the protected and unprotected surgeons, respectively.
Conclusions: This study emphasizes the importance of surgeons wearing lead glove protection on their leading hands during percutaneous vertebroplasty procedures and demonstrates a 75% reduction rate of exposure to radiation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3171/spi.2006.4.2.106 | DOI Listing |
Sci Prog
January 2025
National Fire Research Institute, Asan-si, Republic of Korea.
Firefighters are exposed to the risk of burns at fire scenes. In 2020, the National Fire Agency of the Republic of Korea surveyed 50,527 firefighters and identified 242 burn-related incidents. The body parts affected by these burns were the hands (28.
View Article and Find Full Text PDFCureus
December 2024
Department of Diagnostic Imaging and Radiotherapy, Kulliyyah of Allied Health Sciences, International Islamic University Malaysia, Kuantan Campus, Kuantan, MYS.
In abdominal X-ray examinations, radiosensitive organs such as the gonads within or near the imaging region are at risk of radiation exposure. Minimizing the dose to these organs is crucial to reducing unnecessary radiation. This study utilized optically stimulated luminescence dosimeters (OSLDs) to measure the radiation dose to the male gonads at varying kilovoltage peak (kVp) settings while keeping the milliampere-seconds (mAs) constant across different radiographic projections.
View Article and Find Full Text PDFJ Exp Orthop
January 2025
Department of Orthopedics and Traumatology, Knee Unit, Parc Taulí Hospital Universitari, Institut d'Investigació I Innovació Parc Taulí (I3PT-CERCA) Universitat Autònoma Barcelona (UAB) Sabadell Spain.
Purpose: Tibial valgus osteotomy has shown to be a successful and cost-effective procedure. The advent of image processing and three-dimensional (3D) printing is an interesting tool for achieving more accurate and reproducible results. The aim of our study was to compare the accuracy of the conventional technique and the use of customized guides in the correction of tibial deformities in tibial varus patients, the surgical and clinical benefits, and the impact of treatment in the outpatient setting.
View Article and Find Full Text PDFFront Med (Lausanne)
January 2025
Department of Dermatology, Paediatric Dermatology and Oncology, Medical University of Łódź, Łódź, Poland.
Introduction: Inflammasomes NLRP1 (NLR family pyrin domain containing 1) and NLRP3 are pivotal regulators of the innate immune response, activated by a spectrum of endogenous and exogenous stressors, including ultraviolet radiation (UVR). The precise molecular mechanisms underlying the activation of these inflammasomes remain unclear. Furthermore, the involvement of interleukin-33 (IL-33) in UVR-induced skin carcinogenesis is not well defined.
View Article and Find Full Text PDFQuant Imaging Med Surg
January 2025
Department of Diagnostic and Interventional Radiology, University Hospital Tübingen, Tübingen, Germany.
Background: Clinical severity and progression of lung disease in cystic fibrosis (CF) are significantly influenced by the degree of lung inflammation. Non-invasive quantitative diagnostic tools are desirable to differentiate structural and inflammatory lung changes in order to help prevent chronic airway disease. This might also be helpful for the evaluation of longitudinal effects of novel therapeutics.