A rapid and convenient method for the determination of furfural is presented that is based upon sequential perturbation of the Mn(II)-catalyzed B-Z oscillating system with different amounts of furfural using a continuous-flow stirred tank reactor (CSTR). When the sample was injected, the change in the amplitude and/or period was linearly proportional to the logarithm of the concentration of furfural over the range 3 x 10(-8) approximately 1 x 10(-5) mol L(-1). This method gave a detection limit of 3 x 10(-9) mol L(-1) under optimum conditions. Finally, the possible mechanism of furfural perturbation in the oscillating reaction is discussed. When the furfural was injected into the Mn(II)-catalyzed B-Z oscillating system, the change in the amplitude and/or period was linearly proportional to the logarithm of the concentration of furfural over the range 3 x 10(-8)~1 x 10(-5) mol L(-1), with a detection limit of 3 x 10(-9) mol L(-1) under optimum conditions.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00216-005-0282-4 | DOI Listing |
RSC Adv
January 2025
Department of Chemistry, Faculty of Science, Suez Canal University Ismailia 41522 Egypt +201113343594.
Achieving a net-zero emissions economy requires significant decarbonization of the transportation sector, which depends on the development of highly efficient electrocatalysts. Electrolytic water splitting is a promising approach to this end, with Ni-Mo alloys emerging as strong candidates for hydrogen production catalysts. This study investigates the electrodeposition of Ni and Ni-Mo nanostructured alloys with high molybdenum content onto low-carbon steel cathodes using a novel alkaline green lactate bath.
View Article and Find Full Text PDFLangenbecks Arch Surg
January 2025
Department of Chemical Science & Engineering, School of Materials and Chemical Technology, Institute of Science Tokyo, 2-12-1 Ookayama, Meguro-ku, Tokyo, 152-8552, Japan.
Purpose: We aimed to develop a novel fluorescent surgical gauze dyed with indocyanine green (ICG) to guide surgeons to the target anatomical destination during surgery for real-time navigation and to prevent gauze remnants after surgery.
Methods: Surgical gauze was dyed with an aqueous solution of ICG (5.0 × 10 mol L for Steraze, 1.
Medicine (Baltimore)
November 2024
First Affiliated Hospital of Anhui University of Chinese Medicine, Hefei, Anhui, China.
This study investigates levels of cuproptosis markers in Wilson disease (WD) and their role in the occurrence and development of WD. We retrospectively collected clinical data from 76 patients with Leipzig score ≥ 4 hospitalized in the First Affiliated Hospital of Anhui University of Chinese Medicine from January 2023 to September 2023. The participants were given copper chelators (sodium dimercaptosulphonate (20 mg·kg-1), 4 courses of treatment, 32 days).
View Article and Find Full Text PDFHeliyon
January 2025
Department of Chemistry, School of Physical Sciences, College of Agriculture and Natural Sciences, University of Cape Coast, Cape Coast, Ghana.
Zeolite was successfully synthesized using a mixture of kaolinite clay (which served as the alumina source) and rice husk ash (silica source). The aim of this work was to synthesize highly efficient zelolite to remove methyle blue dye from aqueous solution. The synthesized adsorbent was characterised using Fourier Transform Infrared (FTIR) spectroscopy, powder x-ray diffraction (PXRD) analysis, differential scanning calorimetry (DSC), thermogravimetric analysis (TGA) and pH at the point of zero charge (pHpzc).
View Article and Find Full Text PDFRSC Adv
January 2025
Department of Chemistry, Institute of Technical Education and Research, Siksha 'O' Anusandhan Deemed to Be University Bhubaneswar-751030 Odisha India
The widespread use of neodymium-iron-boron (NdFeB) magnets has raised concerns about the environmental impact of their disposal, prompting the need for sustainable recycling strategies. Traditional solvents used in recycling are toxic and flammable, making them risky to use. Ionic liquids are safer and greener options with low vapor pressure, high stability, and less flammability.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!