Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: As a result of longer follow-up after implantation of cardioverter defibrillators (ICD), fatigue of the leads has become a concern. The aim of this study was to determine the incidence and clinical presentation of ICD lead failures.
Methods And Results: The study population consisted of 241 patients with 249 ICD leads who underwent implantation of an ICD with a transvenous lead system. After device implantation, the patients were routinely followed up every 4 months. Five lead failures (2.0%) occurred as an oversensing of artifact during the follow-up period (2.6+/-2.1 years); 4 of those 5 patients received inappropriate shocks and 1 case of lead failure was identified in a patient with frequent episodes of non-sustained ventricular fibrillation. In particular, the right ventricular polyurethane transvenous lead in the Medtronic model 6936 failed in 4 (13%) of 31 cases. Percutaneous lead extraction was not available in all cases, so an additional ICD lead was inserted through the same site of the subclavian vein.
Conclusions: Lead failures may occur 5 years after ICD implantation and polyurethane leads have an especially high incidence of failure. However, there were no follow-up parameters observed that predicted lead failures.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1253/circj.70.273 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!