Monthly consistency of macular pigment optical density and serum concentrations of lutein and zeaxanthin.

Curr Eye Res

Macular Pigment Research Laboratory, Department of Chemical and Life Sciences, Waterford Institute of Technology, and Department of Ophthalmology, Waterford Regional Hospital, Ireland.

Published: February 2006

Purpose: This study was undertaken to assess serial month-to-month consistency of macular pigment (MP) optical density and serum concentrations of lutein (L) and zeaxanthin (Z). Four healthy subjects aged between 23 and 51 years volunteered to participate in this study.

Methods: MP optical density (measured psychophysically using heterochromatic flicker photometry [HFP]), and serum concentrations of L and Z (quantified using high-performance liquid chromatography [HPLC]), were recorded every month for 24 consecutive months.

Results: Mean MP optical density (+/-SD) was 0.361 (0.086) and 0.369 (0.074) for right and left eyes, respectively. There was no statistically significant seasonal variation in MP optical density for the group (two-way ANOVA: p>0.05). Serum concentrations of L and Z demonstrated a statistically significant subject-season interaction effect (two-way ANOVA: p<0.01). Serial serum concentrations of L and Z were positively correlated within all four subjects (r=0.370 to 0.786), and significantly so for three subjects (p<0.05). There was no obvious relationship, synchronous or lagged, between serum concentrations of L (or Z) and MP optical density (r=-0.036 to 0.368).

Conclusions: MP optical density was relatively stable for all subjects over the 24-month period. Fluctuations in serum concentrations of L and Z, in the absence of dietary modification or supplementation, are associated with stable MP optical density.

Download full-text PDF

Source
http://dx.doi.org/10.1080/02713680500514677DOI Listing

Publication Analysis

Top Keywords

optical density
20
serum concentrations
16
consistency macular
8
macular pigment
8
pigment optical
8
density serum
8
concentrations lutein
8
lutein zeaxanthin
8
two-way anova
8
optical
5

Similar Publications

Magnetic resonance imaging (MRI) is frequently used to monitor disease progression in multiple sclerosis (MS). This study aims to systematically evaluate the correlation between MRI measures and histopathological changes, including demyelination, axonal loss, and gliosis, in the central nervous system of MS patients. We systematically reviewed post-mortem histological studies evaluating myelin density, axonal loss, and gliosis using quantitative imaging in MS.

View Article and Find Full Text PDF

This study uses the Quantum ESPRESSO code to introduce Hubbard correction (U) to the density functional theory (DFT) in order to examine the effects of non-metals (C, F, N, and S) doping on the structural, electronic, and optical characteristics of rutile TiO. Rutile TiO is a substance that shows promise for use in renewable energy production, including fuels and solar energy, as well as environmental cleanup. Its wide bandgap, however, restricts their uses to areas with UV light.

View Article and Find Full Text PDF

Aluminium and its alloys, especially Al6061, have gathered significant interest among researchers due to its less density, great durability, and high strength. Due to their lightweight properties, the precise machining of these alloys can become expensive through conventional machining operations for intricate products. Therefore, non-traditional machining such as electric discharge machining (EDM) can potentially be opted for the cutting of Al6061.

View Article and Find Full Text PDF

Background: Nineteen-year follow-up after initial examination on patients with Axenfeld-Rieger anomaly or syndrome (ARAS) and coexisting Fuchs' endothelial dystrophy (FED). All individuals had previously been tested positive for the PITX2 (g.20 913 G>T) mutation.

View Article and Find Full Text PDF

Background: Loss of corneal endothelial cells after glaucoma surgery can lead to corneal decompensation and reduced vision. This loss may be accelerated by drainage implants like PreserFlo, which allow controlled subconjunctival filtration. In a retrospective analysis, we examined its impact on corneal endothelial cell density (ECD).