The aim of this study was to determine the radiodensity of base, liner and luting dental materials and to compare them with human enamel and dentin. Four classes of materials were examined: conventional glass ionomers (CG)-Vitro Cem, Ketac Bond, Vidrion F, Vidrion C; resin-modified glass ionomers (RMGI)-Fuji II LC, Vitrebond; resinous cement (RC)-Rely-X ARC; and zinc phosphate cement (ZP)-Cimento LS. Five 2-mm-thick standard samples of each material and five 2-mm-thick enamel and dentin samples were produced. An aluminum step wedge served as control. Samples were positioned over a phosphor plate of Digora digital system, exposed to X-ray, and the radiodensity obtained in the software Digora for Windows 2.0. Data were submitted to Kruskal-Wallis and Dunnett multiple comparisons test (alpha=0.05). According to statistical analysis, the following sequence in degree of radiodensity could be seen among the groups: Cimento LS (ZP) > Vitro Cem (CG) = Fuji II LC (RMGI) = Rely-X ARC (RC) = Vitrebond (RMGI) > Ketac Bond (CG) > enamel = Vidrion F (CG) > Vidrion C (CG) = dentin. The presence of radiopaque fillers such as zinc, strontium, zirconium, barium, and lanthanium rather than material type seems to be the most important factor when analyzing material radiodensity. Almost all investigated materials presented an accepted radiodensity.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00784-005-0030-3 | DOI Listing |
Oper Dent
March 2024
*Carlos José Soares, DDS, MS, PhD, Department of Operative Dentistry and Dental Materials, School of Dentistry, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil.
Objectives: To evaluate the effect of the different radiant exposures from a multipeak light curing unit on the physical and mechanical properties of flowable and high-viscosity bulk-fill resin-based composites (RBC).
Methods: Five flowable bulk-fill RBCs (Tetric N-Flow Bulk-fill, Ivoclar Vivadent; Filtek Bulk Fill Flow, 3M Oral Care; Opus Bulk Fill Flow APS, FGM; Admira Fusion x-base, Voco and; and SDR Plus Bulk Fill Flowable, Dentsply Sirona) and five high-viscosity bulk-fill RBCs (Tetric N-Ceram Bulk-fill, Ivoclar Vivadent; Filtek One Bulk Fill, 3M Oral Care; Opus Bulk Fill APS, FGM; Admira Fusion x-tra, Voco; and SonicFill 2, Kerr) were photo-cured using a VALO Cordless light (Ultradent) for 10, 20, and 40 seconds at an irradiance of 1200, 800, or 400 mW/cm2, resulting in the delivery of 4, 8, 12, 16, 24, 32, or 48 J/cm2. Post-gel shrinkage (Shr) was calculated using strain-gauge test.
Bioengineering (Basel)
October 2022
Department of Engineering, Eindhoven University of Technology (TU/e), 5612 Eindhoven, The Netherlands.
Background: Neurosurgical procedures are complex and require years of training and experience. Traditional training on human cadavers is expensive, requires facilities and planning, and raises ethical concerns. Therefore, the use of anthropomorphic phantoms could be an excellent substitute.
View Article and Find Full Text PDFClin Oral Investig
July 2021
Conservative Dentistry Department, Faculty of Dentistry, Alexandria University, Alexandria, Egypt.
Objectives: To assess clinically and radiographically the success of pulp capping procedure done in traumatically exposed permanent posterior teeth using a novel injectable treated dentin matrix hydrogel (TDMH), Biodentine, and MTA and to evaluate the formed dentin bridge under the capping materials using CBCT imaging.
Materials And Methods: 45 patients subjected to accidental traumatic pulp exposures by undergraduate dental students are allocated for this study. For each patient, a pulp capping procedure was done.
Laryngoscope Investig Otolaryngol
August 2020
Geisel School of Medicine at Dartmouth Hanover New Hampshire USA.
Objective: With the paradigm shift towards minimally invasive surgical techniques such as transoral laser microsurgery and transoral robotic surgery for resection of head and neck malignancies, there is a need to enhance the surgical training of these techniques as well as provide a platform for testing new approaches and technologies. The steeper learning curve associated with minimally invasive surgical techniques may be mitigated with the use of tumor phantoms (TP) placed in cadaver models.
Methods: An injectable TP was developed using an agar-gelatin base, unsalted chicken stock, deionized water, food coloring for visual mimicry, and iohexol for radiographic mimicry.
Front Oncol
August 2020
Department of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
Purpose: Gastric sarcomatoid carcinoma (GSC) is a very rare malignant tumor. The purpose of this study is to describe the clinical, computed tomography (CT), and pathologic features of GSC to increase awareness of this entity.
Methods: The CT features and clinical data of five patients with pathologically documented GSC were retrospectively analyzed and compared with the corresponding data of gastric adenocarcinoma and lymphoma.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!