Wrong gas/liquid partition data by gas chromatography.

J Chromatogr A

Ecole Polytechnique Fédérale de Lausanne, CH-1015 Lausanne, Switzerland.

Published: April 2006

In a paper published in 1992 [K.S. Reddy, J.-Cl. Dutoit, E.sz. Kováts, Pair-wise interactions by gas chromatography. I. Interaction free enthalpies of solutes with non-associated primary alcohol groups, J. Chromatogr. 609 (1992) 229] retention indices and standard chemical potential differences (SPOT-s) are given for about 160 solutes on a liquid branched paraffin hydrocarbon of the carbon number, z = 78. For the temperature dependence of the SPOT-s the proposal of Kirchhoff was accepted i.e. that at higher temperatures the molar heat capacity difference of the solute between the gas phase and the solution is nearly constant in a broad temperature range. The data were determined under conditions where the effect of adsorption could be neglected. By comparing the published data with those determined on another branched paraffin of the carbon number, z = 87 [F. Riedo, D. Fritz, G. Tarján, E.sz. Kováts, A tailor-made C87 hydrocarbon as a possible non-polar standard stationary phase for gas chromatography, J. Chromatogr. 126 (1976) 63] it is shown that the reported thermodynamic constants of solutes determined experimentally at higher temperatures (the group "H") are wrong on C78. In the present paper, the method of correction and the resulting corrected data are given. In later papers retention data are given on eight polar derivatives of the hydrocarbon C78 relative to those measured on the nonpolar standard [R. Cloux, G. Défayes, K. Fóti, J.-Cl. Dutoit, E.sz. Kováts, Pair-wise interactions by gas chromatography. III. Synthesis of isosteric stationary phases for gas chromatography, Synthesis (1993) 909; G. Défayes, K.S. Reddy, A. Dallos, E.sz. Kováts, Pair-wise interactions by gas chromatography. V. Interaction free enthalpies of solutes with primary chloro- and bromo-alkanes, J. Chromatogr. A 699 (1995) 131; K.S. Reddy, E.sz. Kováts, Pair-wise interactions by gas chromatography. II. Sociation free enthalpies of some hydrogen bonding solutes with non-associated primary alcohol groups, Chromatographia 34 (1992) 249; K.S. Reddy, R. Cloux, E.sz. Kováts, Pair-wise interactions by gas chromatography. IV. Interaction free enthalpies of solutes with trifluoromethyl-substituted alkanes, J. Chromatogr. A 673 (1994) 181; K.S. Reddy, R. Cloux, E.sz. Kováts, Pair-wise interactions by gas chromatography. VI. Interaction free enthalpies of solutes with primary methoxyalkane, cyanoalkane and alkanethiol groups, J. Chromatogr. A 704 (1995) 387; A. Dallos, A. Sisak, Z. Kulcsár, E.sz. Kováts, Pair-wise interactions by gas chromatography. VII. Interaction free enthalpies of solutes with secondary alcohol groups, J. Chromatogr. A 904 (2000) 211]. Obviously, the same data which are wrong in the nonpolar standard are also wrong in these solvents. The corrected data in the polar solvents are given in supplementary tables.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2006.01.123DOI Listing

Publication Analysis

Top Keywords

gas chromatography
40
esz kováts
32
kováts pair-wise
28
pair-wise interactions
28
interactions gas
28
free enthalpies
24
interaction free
20
enthalpies solutes
20
chromatography interaction
16
alcohol groups
12

Similar Publications

Pyrethroids are synthetic chemicals that account for 16% of the international insecticide market and have been shown to be of varying toxicity to different species. There are various methods available for detecting pyrethroids in agricultural products, but these products must be pre-treated to remove interference from the food matrix, such as through dispersion liquid-liquid microextraction (DLLME). This study employed two experimental design methods to optimize the continuous and discontinuous experimental parameters of DLLME and investigated whether DLLME combined with GC-NICI-MS is effective for detecting pyrethroids in agricultural products.

View Article and Find Full Text PDF

Infectious diseases remain a major global health concern. Cistus ladanifer, a plant commonly employed in Moroccan traditional medicine, has been identified as a potential antiviral candidate. This study aimed to evaluate the antiviral activity of C.

View Article and Find Full Text PDF

Background The synthetic opioid tramadol is widely used as a pain reliever. Unlike other opioids, it is used freely worldwide, unaffected by international controls resulting in abuse and accidental intoxication. Analytical methods are necessary to prove tramadol abuse because 30% of the drug is excreted unchanged.

View Article and Find Full Text PDF

Time-efficient HPLC Validation Methodology for the Qualitative Analysis of 68Ga PSMA-11 in Routine Clinical Usage under Isocratic Method.

Indian J Nucl Med

November 2024

Department of Nuclear Medicine and Molecular Imaging, Homi Bhabha Cancer Hospital and Mahamana Pandit Madan Mohan Malaviya Cancer Centre, Tata Memorial Centre, Homi Bhabha National Institute, Varanasi, Uttar Pradesh, India.

Background: Prostate-specific membrane antigen (PSMA) has shown to be a promising agent for prostate cancer imaging under PET-CT. With the automation in radiolabeling with 68Ga, using iTG 68Ge/68Ga generator, it has helped introduce various new diagnostic agents and achieve good manufacturing practices (GMP) simultaneously. However, before any radiopharmaceutical is put into clinical usage, it should always be checked for its radiochemical purity and other quality parameters before injecting in the patient.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!