Introduction: Ureteroscopic pneumatic lithotripsy has been used to treat ureteral calculi for more than 10 years. Owing to its low price and high degree of effectiveness, it has become the most popular ureteroscopic lithotripsy device in use worldwide. The major limitation of the technique is the occurrence of proximal fragment migration during intracorporeal lithotripsy. The Dretler Stone Cone is a new device developed to prevent stone migration during ureteroscopic lithotripsy. The aim of this study was to assess the efficacy and safety of this device during ureteroscopic pneumatic lithotripsy.
Patients And Methods: Twenty-three consecutive patients having ureteral stones were treated with a 10-Fr semirigid ureteroscope, a Stone Cone Nitinol Retrieval Device, and a pneumatic lithotriptor. In all patients Stone Cones were placed under visual guidance through the working channel of the ureteroscope. Outcomes of this device were then compared with the outcomes of 23 previous patients with stones of similar sizes and locations who had undergone ureteroscopic pneumatic lithotripsy prior to the Stone Cone being available at our clinic.
Results: All patients in the study group were stone-free after the procedure. No stone fragments were noted to migrate to proximal segments.
Conclusions: The Dretler Stone Cone effectively prevents proximal stone migration and facilitates stone fragmentation during pneumatic lithotripsy with no risk of ureteral injury. It has only a small extra cost.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1159/000090881 | DOI Listing |
J Oral Biol Craniofac Res
November 2024
Ramaiah University of Applied Sciences (RUAS), Bengaluru, India.
Objective: This study aimed to compare a direct conventional 3D digital technique vis a vis a hybrid method in measuring palatal volume.
Materials And Methods: Thirty maxillary casts were obtained from the records of patients undergoing orthodontic treatment and pre-conceived boundaries of the palatal vault were marked. Sample was categorised into Group I (Volume estimation using CBCT scan) and Group II (Volume estimation using hybrid method).
Br J Radiol
November 2024
Department of Hepatobiliary Surgery, The Second People's Hospital of Foshan, Foshan, 528000, Guangdong Province.
Objective: Dyna computed tomography (DynaCT) is an innovative clinical imaging tool used to obtain three-dimensional (3D) images of biliary structures via the Artis Zee DSA system (SIEMENS Company, Germany). DynaCT is a type of 3D cone beam computed tomography (CBCT) reconstruction produced from a two-dimensional (2D) cholangiography system by rotating the C-arm without moving the patient. The aim of this study was to evaluate the technical approach and application value of DynaCT to diagnosis hepatolithiasis and biliary stenosis.
View Article and Find Full Text PDFMinim Invasive Ther Allied Technol
December 2024
Department of Hepatobiliary and Pancreatic Surgery, Sichuan People's Hospital, School of Medicine, University of Electronic Science and Technology of China.
HGG Adv
January 2025
Institute for Vision Research, Carver College of Medicine, University of Iowa, Iowa City, IA, USA; Department of Ophthalmology and Visual Sciences, Carver College of Medicine University of Iowa, Iowa City, IA, USA. Electronic address:
Dent Traumatol
September 2024
Department of Operative Dentistry and Dental Materials, Dental School, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!