Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Intrathecal (IT) baclofen is an effective management strategy for controlling spasticity in patients unresponsive to maximal oral therapy. We present the case of a 57-yr-old woman who was rendered quadriplegic after a complete spinal cord transection at the C6 level. Her course was complicated by severe spasms, which were uncontrolled despite titrating orally administered baclofen to 80 mg/d. IT baclofen testing was performed with good response, and administration was commenced via an implanted intrathecal pump 6 mo after the injury at an initial dose of 200 microg/d. Catheter revision was required 2 wk later as a result of catheter displacement. The initial IT baclofen dose was gradually increased to achieve good control at a level of 400 microg/d. After a period of stability lasting 38 mo, her lower limb spasms dramatically increased in severity and remained poorly controlled despite repeated dose increases. Contrast pumpogram and computed tomography myelogram were performed to exclude a mechanical cause for this apparent increase in baclofen requirement. These investigations revealed neither catheter displacement nor fracture as suspected but, rather, displayed the presence of a catheter tip-associated mass. Catheter tip granuloma has not previously been described in a patient receiving IT baclofen alone. This suggests that although uncommon, the possibility of catheter-associated granuloma must be considered in all patients receiving IT baclofen presenting with altered neurological function or significant increase in drug requirement.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1213/01.ane.0000196523.06573.10 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!