The physics of computed radiography: measurements of pulse height spectra of photostimulable phosphor screens using prompt luminescence.

Med Phys

Sunnybrook and Women's College Health Sciences Centre, Department of Medical Biophysics, University of Toronto, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5, Canada.

Published: December 2005

Computed radiography (CR) is a digital technology that employs reusable photostimulable phosphor (PSP) imaging plates (IP) to acquire radiographic images. In CR, the x-ray attenuation pattern of the imaged object is temporarily stored as a latent charge image within the PSP. The latent image is optically readout as photostimulated luminescence (PSL) when the phosphor is subsequently stimulated using a scanning laser. The multiple stages necessary to create a CR image make it difficult to investigate either experimentally or theoretically. In order to examine the performance of the CR system at a fundamental level separate measurements of the processes involved are desirable. Here pulse height spectroscopy is used to study the prompt violet light emission or prompt luminescence (PL) from commercial PSP screens. Since the mechanism by which light escapes from the phosphor is identical for PL and PSL, observations and conclusions based on the pulse height spectra (PHS) of PL are relevant to the understanding of the behavior of the PSL light emission that outputs the radiographic image in CR. The PL PHS of screens of different thickness and optical properties were measured and compared with the PHS of conventional phosphors. A new method for calibration of the PHS in terms of the absolute number of optical photons per x-ray is introduced and compared to previously established methods.

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.2122587DOI Listing

Publication Analysis

Top Keywords

pulse height
12
computed radiography
8
height spectra
8
photostimulable phosphor
8
prompt luminescence
8
light emission
8
physics computed
4
radiography measurements
4
measurements pulse
4
spectra photostimulable
4

Similar Publications

Red blood cell distribution width (RDW) has recently been recognized as a novel biomarker associated with various cardiovascular conditions. This study aims to investigate the relationship between RDW and carotid-femoral pulse wave velocity (cfPWV) in a southern Chinese population. A total of 4916 patients were initially enrolled from the First Affiliated Hospital of Fujian Medical University between January 2016 and December 2022.

View Article and Find Full Text PDF

Background: Obesity and metabolic syndrome (MS) accelerate arterial stiffening, increasing cardiovascular (CV) risk after transplant. BMI is limited by inability to differentiate muscle, fat mass, and fat distribution patterns. The aim of this study was to identify the best anthropometric measure to detect arterial stiffness as assessed by pulse wave velocity (PWV) in a racially diverse pediatric transplant population.

View Article and Find Full Text PDF

Purpose: To evaluate the efficacy and safety of intense pulsed light (IPL) combined with meibomian gland expression (MGX) for the treatment of dry eye disease and meibomian gland dysfunction associated with chronic Stevens-Johnson syndrome and toxic epidermal necrolysis.

Methods: This prospective noncomparative interventional study included 29 patients (58 eyes) who underwent 3 sessions of IPL and MGX at 2-week intervals. Subjective symptoms (ocular surface disease index score) and objective dry eye tests: matrix metalloproteinase 9, tear meniscus height, bulbar redness score, tear film lipid layer thickness (LLT), Schirmer I test, conjunctival and corneal staining, meibomian gland loss, MGX score [meibomian gland score (MGS)], and tear break-up time were assessed at the baseline and after 4, 8, and 12 weeks.

View Article and Find Full Text PDF

Evidence for low bioavailability of dietary nanoparticulate cerium in a freshwater food chain.

Aquat Toxicol

December 2024

ANSTO, Nuclear Science and Technology Division, Lucas Heights, NSW 2234, Australia.

Radioactive Ce in ionic (I-Ce), nano (N-Ce, 11 ± 9 nm mean primary particle size ± standard deviation) and micron-sized (M-Ce, 530 ± 440 µm) forms associated with natural and artificial diets in natural river water and synthetic freshwater were used to measure the real-time biokinetics of dietary Ce assimilation in a freshwater food chain. The model food chain consisted of microalgae (Raphidocelis subcapitata), snails (Potamopyrgus antipodarum) and prawns (Macrobrachium australiense). Pulse-chase experiments showed that 91-100 % of all forms of cerium associated with all diets and water types were eliminated from the digestive system of the snail and prawn within 24 h, with no detectable cerium assimilation.

View Article and Find Full Text PDF

Transducers used in acoustic logging while drilling (ALWD) must be mounted on a drill collar, and their radiation performance is dependent on the employed mounting method. Herein, the complex transmitting voltage response of a while-drilling (WD) monopole acoustic source was calculated through finite-element harmonic-response analysis. Subsequently, the acoustic pressure waveform radiated by the source driven by a half-sine excitation voltage signal was calculated using the complex transmitting voltage response.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!