Two classes of anthropomorphic computational phantoms exist for use in Monte Carlo radiation transport simulations: tomographic voxel phantoms based upon three-dimensional (3D) medical images, and stylized mathematical phantoms based upon 3D surface equations for internal organ definition. Tomographic phantoms have shown distinct advantages over the stylized phantoms regarding their similarity to real human anatomy. However, while a number of adult tomographic phantoms have been developed since the early 1990s, very few pediatric tomographic phantoms are presently available to support dosimetry in pediatric diagnostic and therapy examinations. As part of a larger effort to construct a series of tomographic phantoms of pediatric patients, five phantoms of different ages (9-month male, 4-year female, 8-year female, 11-year male, and 14-year male) have been constructed from computed tomography (CT) image data of live patients using an IDL-based image segmentation tool. Lungs, bones, and adipose tissue were automatically segmented through use of window leveling of the original CT numbers. Additional organs were segmented either semiautomatically or manually with the aid of both anatomical knowledge and available image-processing techniques. Layers of skin were created by adding voxels along the exterior contour of the bodies. The phantoms were created from fused images taken from head and chest-abdomen-pelvis CT exams of the same individuals (9-month and 4-year phantoms) or of two different individuals of the same sex and similar age (8-year, 11-year, and 14-year phantoms). For each model, the resolution and slice positions of the image sets were adjusted based upon their anatomical coverage and then fused to a single head-torso image set. The resolutions of the phantoms for the 9-month, 4-year, 8-year, 11-year, and 14-year are 0.43 x 0.43 x 3.0 mm, 0.45 x 0.45 x 5.0 mm, 0.58 x 0.58 x 6.0 mm, 0.47 X 0.47 x 6.00 mm, and 0.625 x 0.625 x 6.0 mm, respectively. While organ masses can be matched to reference values in both stylized and tomographic phantoms, side-by-side comparisons of organ doses in both phantom classes indicate that organ shape and positioning are equally important parameters to consider in accurate determinations of organ absorbed dose from external photon irradiation. Preliminary studies of external photon irradiation of the 11-year phantom indicate significant departures of organ dose coefficients from that predicted by the existing stylized phantom series. Notable differences between pediatric stylized and tomographic phantoms include anterior-posterior (AP) and right lateral (RLAT) irradiation of the stomach wall, left lateral (LLAT) and right lateral (RLAT) irradiation of the thyroid, and AP and posterior-anterior (PA) irradiation of the urinary bladder.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1118/1.2107067 | DOI Listing |
Phys Med
January 2025
Department of Physics "A. Pontremoli", University of Milan & INFN sez. Milano, Milano, Italy. Electronic address:
Purpose: This work aims at investigating, via in-silico evaluations, the noise properties of an innovative scanning geometry in cone-beam CT (CBCT): eCT. This scanning geometry substitutes each of the projections in CBCT with a series of collimated projections acquired over an oscillating scanning trajectory. The analysis focused on the impact of the number of the projections per period (PP) on the noise characteristics.
View Article and Find Full Text PDFJ Med Imaging (Bellingham)
January 2025
University of Houston, Department of Biomedical Engineering, Houston, Texas, United States.
Purpose: Digital phantoms are one of the key components of virtual imaging trials (VITs) that aim to assess and optimize new medical imaging systems and algorithms. However, these phantoms vary in their voxel resolution, appearance, and structural details. We investigate whether and how variations between digital phantoms influence system optimization with digital breast tomosynthesis (DBT) as a chosen modality.
View Article and Find Full Text PDFJ Med Imaging (Bellingham)
December 2024
University of Houston, Department of Physics, Houston, Texas, United States.
Purpose: Photon counting detectors offer promising advancements in computed tomography (CT) imaging by enabling the quantification and three-dimensional imaging of contrast agents and tissue types through simultaneous multi-energy projections from broad X-ray spectra. However, the accuracy of these decomposition methods hinges on precise composite spectral attenuation values that one must reconstruct from spectral micro-CT. Errors in such estimations could be due to effects such as beam hardening, object scatter, or detector sensor-related spectral distortions such as fluorescence.
View Article and Find Full Text PDFMed Phys
December 2024
Department of Physics, Lakehead University, Thunder Bay, Ontario, Canada.
Background: This study investigates a multi-angle acquisition method aimed at improving image quality in organ-targeted PET detectors with planar detector heads. Organ-targeted PET technologies have emerged to address limitations of conventional whole-body PET/CT systems, such as restricted axial field-of-view (AFOV), limited spatial resolution, and high radiation exposure associated with PET procedures. The AFOV in organ-targeted PET can be adjusted to the organ of interest, minimizing unwanted signals from other parts of the body, thus improving signal collection efficiency and reducing the dose of administered radiotracer.
View Article and Find Full Text PDFIEEE Sens J
April 2024
Department of Mathematics and the School of Biomedical Engineering, Colorado State University, Fort Collins, CO 80523 USA.
Pulmonary imaging with ultrasound in the conventional MHz range suffers from significant artifacts, as the high frequency acoustic waves primarily reflect off of the lung pleura with little to no penetration through the lung tissue. Furthermore, B-mode ultrasound images are difficult to interpret and require a skilled technician to obtain. Motivated by the finding that acoustic frequencies in the kHz penetrate lung tissue, a low-frequency tomographic ultrasound system is presented.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!