The case report demonstrates the value of multslice computed tomography for stent imaging and detection of an in-stent stenosis in an infant with pulmonary atresia and ventricular septal defect after stent placement in the right pulmonary artery after biventricular repair.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ccd.20644DOI Listing

Publication Analysis

Top Keywords

computed tomography
8
in-stent stenosis
8
stenosis infant
8
multislice computed
4
tomography adjunct
4
adjunct management
4
management in-stent
4
infant congenital
4
congenital heart
4
heart disease
4

Similar Publications

Cochlear Implant Electrode Placement and Music Perception.

JAMA Otolaryngol Head Neck Surg

January 2025

Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, Tennessee.

Importance: Cochlear implants enable improvements in speech perception, but music perception outcomes remain variable. Image-guided cochlear implant programming has emerged as a potential programming strategy for increasing the quality of spectral information delivered through the cochlear implant to improve outcomes.

Objectives: To perform 2 experiments, the first of which modeled the variance in music perception scores as a function of electrode positioning factors, and the second of which evaluated image-guided cochlear implant programming as a strategy to improve music perception with a cochlear implant.

View Article and Find Full Text PDF

Background: Laparoscopic gastrectomy lacks hand-direct tactile sense and has a limited surgical field compared to laparotomy. Apart from textbook classification, there are anatomical variations in the gastric arteries. Laparoscopic gastrectomy presents technical difficulties and necessitates a more comprehensive comprehension of regional anatomy than open surgical procedures.

View Article and Find Full Text PDF

Objectives: To develop and validate the performance of CT-based radiomics models for predicting the prognosis of acute pancreatitis.

Methods: All 344 patients (51 ± 15 years, 171 men) in a first episode of acute pancreatitis (AP) were retrospectively enrolled and randomly divided into training (n = 206), validation (n = 69), and test (n = 69) sets with the ratio of 6:2:2. The patients were dichotomized into good and poor prognosis subgroups based on follow-up CT and clinical data.

View Article and Find Full Text PDF

Background: Hepatic artery infusion pump (HAIP) chemotherapy is a locoregional treatment for intrahepatic malignancies. HAIPs are surgically implanted, and the catheter tip is typically inserted into a ligated gastroduodenal artery stump. Potential complications at the catheter insertion site include dehiscence, pseudoaneurysm or extravasation, and adjacent hepatic arterial stenosis and thrombosis.

View Article and Find Full Text PDF

Biomarkers.

Alzheimers Dement

December 2024

Roche Diagnostics International AG, Rotkreuz, Zug, Switzerland.

Background: Use of neuroimaging [e.g. magnetic resonance imaging (MRI), positron emission tomography (PET), or computed tomography (CT) scan], cerebrospinal fluid (CSF), and blood biomarker tests can contribute to a more accurate and earlier diagnosis of Alzheimer's disease (AD).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!