Statement Of Problem: Despite their esthetic properties, the fracture resistance of newly introduced esthetic post-and-core systems has not been studied, restricting clinical use.
Purpose: The purpose of this study was to determine and compare the fracture resistances of 3 recently introduced esthetic post-and-core systems with a cast metal post and core using a clinically related test method.
Material And Methods: Forty recently extracted caries-free maxillary central incisors were selected, sectioned, and their roots endodontically treated. The roots were then embedded in acrylic resin blocks and assigned to 4 experimental groups (n = 10). The cast metal (Wiron 99) post-and-core group (CMDC) served as the control. Three experimental groups consisted of a stainless steel post/composite-resin (Charisma) core group (SCOM), zirconium dioxide post/composite-resin (Charisma) core group (ZCOM), and zirconium dioxide post/ceramic (Cosmopost) core group (ZCER). The post spaces were prepared, posts were seated, cores were formed, and 40 post-and-core foundations were cemented into the roots. Following thermal cycling (5000 cycles between 5 degrees C and 55 degrees C with a dwell time of 30 seconds), a compressive load was applied to the inclined surface of each specimen at a 130-degree angle to the specimen long axes in a universal testing machine at a crosshead speed of 1 mm/min until failure occurred. Force to failure (N) was recorded. Data were analyzed with a 1-way analysis of variance and Bonferroni tests to determine the difference between the groups (alpha=.05). For pairwise comparisons among group mean values, P < .0083 indicated statistical significance and established the overall confidence level at 95%.
Results: Groups CMDC (738.6 N +/- 10.2) and ZCER (710.2 N +/- 5.3) exhibited the highest resistance to fracture. The ZCOM group showed the lowest fracture resistance (450.3 N +/- 5.7). The fracture resistance of the SCOM group (565 N +/- 7.2) was lower than the CMDC and ZCER groups, and higher than the ZCOM group. The differences among the groups were significant (P < .001) except for CMDC and ZCER (P < .016).
Conclusion: Within the limitations of this study, the cast metal post/core and zirconia post/ceramic core foundations were found to be more fracture resistant than the zirconia post/composite-resin core and stainless steel post/composite-resin core foundations. Aside from its desirable esthetic properties, the zirconia post/ceramic core combination demonstrated high resistance to fracture.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.prosdent.2005.11.013 | DOI Listing |
Cureus
November 2024
Conservative Dentistry and Endodontics, Mahe Institute of Dental Sciences and Hospital, Mahe, IND.
Endodontically treated teeth with compromised coronal tooth structure often require core build-ups with the support of radicular posts. In certain cases, the traditional post and core approach may not be possible due to various anatomical and clinical contraindications. Such cases require more meticulous planning and alternative treatment approaches for successful outcomes.
View Article and Find Full Text PDFCureus
November 2024
Dentistry, College of Dentistry, King Saud University, Riyadh, SAU.
Endodontically treated molar rehabilitation is still challenging. Molars lose their mechanical properties after endodontic therapy. As a result of the pulp and surrounding dentin tissues being removed, they actually became brittle.
View Article and Find Full Text PDFBMC Oral Health
November 2024
Department of Stomatology, The First Medical Center, Chinese PLA General Hospital, No.28 Fuxing Road, Haidian District, Beijing, 100853, China.
Background: Pulp canal occlusion (PCO) increases the difficulty of root canal treatment as well as tooth preservation and restoration. This is the first case report of successful localization of a calcified root canal under the guidance of a dynamic navigation system (DNS) for complete root canal retreatment and aesthetic restoration after a failed attempt to locate the calcified root canal with a traditional dental operating microscope (DOM).
Case Presentation: The patient was scheduled for root canal treatment for a labially inclined maxillary central incisor and post-core crown restoration with resin veneers in another hospital, but the calcified root canal could not be located with a microscope, so the patient was referred to our department.
Clin Exp Dent Res
October 2024
Social Determinants of Health Research Center, Health Research Institute, Babol University of Medical Sciences, Babol, Iran.
Objective: The demand for esthetics has increased in today's world and most parents prefer to preserve their children's primary anterior teeth until their natural exfoliation. However, an intracanal post is required to provide retention for reconstruction of severely damaged anterior teeth due to caries or trauma. Various materials and methods may be used for the fabrication of intracanal posts.
View Article and Find Full Text PDFMaterials (Basel)
July 2024
Faculty of Dental Surgery, University of Paris Cité, 75006 Paris, France.
The restoration of endodontically treated teeth (ETT) remains a significant challenge in modern dentistry. These teeth often suffer from substantial structural damage due to both the original pathology and the invasive nature of endodontic procedures. Consequently, ETT are more susceptible to fractures compared to vital teeth, necessitating restorative strategies that can effectively restore both function and aesthetics while minimizing the risk of failure.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!