A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effect of pH and temperature on orthodontic NiTi wires immersed in acidic fluoride solution. | LitMetric

Effect of pH and temperature on orthodontic NiTi wires immersed in acidic fluoride solution.

J Biomed Mater Res B Appl Biomater

Department of Dental Materials, College of Dentistry and Medical Research Institute, Pusan National University, Pusan 602-739 Korea.

Published: October 2006

Orthodontic arch wires can confront diverse pH and temperature conditions in the oral cavity after replacement. The current study evaluated the effect of pH and temperature on orthodontic NiTi arch wires after immersion in an acidic fluoride solution. The acetic acid added for the adjustment of pH forms hydrofluoric acid (HF). More HF was formed in a solution of lower pH with higher temperature than that of the higher pH with lower temperature. Within the same pH value, the temperature of the solution affected the concentration of HF. Each as-received wire exhibited quite different microhardness values. The reduction of microhardness, 1.2-5.7%, occurred after immersion. Within the same product, however, the pH and temperature had minor influence on the reduction. The volumetric weight change, concentration of the released elements, and surface morphology were influenced by pH and temperature. At pH 3.5 of 60 degrees C solution, the greatest weight loss, release of elements, and corrosion of surface occurred from the wires. At pH 6, on the other hand, no such loss or release occurred regardless of temperature. At 5 degrees C solution, the surface exhibited minor corrosion regardless of pH value.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jbm.b.30505DOI Listing

Publication Analysis

Top Keywords

temperature
9
temperature orthodontic
8
orthodontic niti
8
acidic fluoride
8
fluoride solution
8
arch wires
8
temperature degrees
8
degrees solution
8
loss release
8
solution
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!