Download full-text PDF

Source
http://dx.doi.org/10.1080/17453670510045336DOI Listing

Publication Analysis

Top Keywords

removal retention--will
4
retention--will know?
4
know? posterior
4
posterior cruciate
4
cruciate ligament
4
ligament total
4
total knee
4
knee replacement
4
removal
1
know?
1

Similar Publications

Background The aim of this study was to evaluate the clinical and radiological results of patients with acute type III Rockwood acromioclavicular joint (ACJ) dislocation treated surgically by employing tension band wiring. Methods The study included 24 patients with traumatic type III ACJ dislocations according to the Rockwood classification. The clinical and radiological outcomes of patients were assessed at the final follow-up visit.

View Article and Find Full Text PDF

Modern views of anesthetic neurosteroid interaction with the GABA(A) receptor conceptualize steroid ligands interacting with a protein binding site on the receptor. It has generally been assumed that the steroid interaction/binding site is contained in an extracellular domain of the receptor, and that steroid interactions are of high potency, evidenced by the low aqueous ligand concentrations required to achieve potentiation of channel function. We have been considering implications of the observations that steroids are quite lipophilic and that recently identified putative steroid binding sites are in transmembrane domains of the receptor.

View Article and Find Full Text PDF

Implant supported restorations can be attached to implants with screws or can be cemented to abutments which are secured to implants with screws. Screw retained implant restorations are the authors' preferred method of securing restorations to implants. This article will be written from this perspective and the advantages and disadvantages of each method of retention will be discussed under the following headings: Aesthetics, Retrievability, Retention, Implant placement, Passivity, Provisionals, Occlusion, Immediate loading, Impression procedures, Long term treatment planning.

View Article and Find Full Text PDF

Primary end-to-end infrarenal aortic anastomoses were performed in 36 piglets using two synthetic absorbable suture materials: polydioxanone and coated polyglactin. Animals were killed at 1, 4, and 11 weeks and 6 months following operation. Each aorta was removed, burst-tested to 300 mm Hg, radiographed, and examined histologically.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!