Real-time contrast-enhanced sonography (RT-CES) can assess microvascular tissue perfusion using gas-filled microbubbles. The study was performed to evaluate the feasibility of RT-CES in detecting chronic allograft nephropathy (CAN) in comparison to color Doppler ultrasonography (CDUS). A total of 26 consecutive renal transplant recipients were prospectively studied using RT-CES and conventional CDUS. Transplant tissue perfusion imaging was performed by low-power imaging during i.v. administration of the sonocontrast Optison. Renal tissue perfusion was assessed quantitatively using flash replenishment kinetics of microbubbles to estimate renal blood flow A *beta (A = peak signal intensity, beta= slope of signal intensity rise). In contrast to conventional CDUS resistance and pulsatility indices, renal blood flow estimated by CES was highly significant related to S-creatinine (r =-0.62, p = 0.0004). Determination of renal blood flow by CES reached a higher sensitivity (91% vs. 82%, p < 0.05), specificity (82% vs. 64%, p < 0.05) and accuracy (85% vs. 73%, p < 0.05) for the diagnosis of CAN as compared to conventional CDUS resistance indices. Perfusion parameters derived from RT-CES significantly improve the early detection of CAN compared to conventional CDUS. RT-CES using low-power real-time perfusion imaging is a feasible method to evaluate microvascular perfusion in renal allograft recipients.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1600-6143.2005.01224.xDOI Listing

Publication Analysis

Top Keywords

conventional cdus
16
tissue perfusion
12
renal blood
12
blood flow
12
real-time contrast-enhanced
8
contrast-enhanced sonography
8
renal transplant
8
transplant recipients
8
chronic allograft
8
allograft nephropathy
8

Similar Publications

Conventional ultrasonography (US), including greyscale imaging and colour Doppler US (CDUS), is pivotal for diagnosing scrotal pathologies, but it has limited specificity. Historically, solid focal testicular abnormalities often led to radical orchidectomy. This retrospective study evaluated the utilisation of contrast-enhanced ultrasound (CEUS) and strain elastography (SE) in investigating intratesticular focal abnormalities.

View Article and Find Full Text PDF

Diagnostic Performance of Contrast-Enhanced Ultrasound in Testicular Space-Occupying Lesions: A Systematic Review and Meta-analysis.

Acad Radiol

November 2024

Department of Ultrasound, The Second Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, Jiangxi, China. Electronic address:

Purpose: Contrast-enhanced ultrasound (CEUS) has been increasingly used for the diagnostic identification of neoplasms due to its ability to visualize the microvascularization of lesions. In the study of testicular abnormalities, the appropriate use of CEUS can improve the diagnostic accuracy of conventional gray-scale ultrasound and color Doppler ultrasound (CDUS). The purpose of this study is to comprehensively evaluate the diagnostic performance of CEUS in testicular space-occupying lesions.

View Article and Find Full Text PDF

Purpose: This study aimed to assess the feasibility of contrast-enhanced ultrasound (CEUS) for the diagnosis of acute pyelonephritis (APN) in pediatric patients with febrile urinary tract infection (UTI).

Materials And Methods: Between March 2019 and January 2021, study participants with suspected UTI were assessed for APN using ultrasound. Parenchymal echogenicity changes, renal pelvis dilatation, and the presence of a focal suspected lesion were assessed using conventional grayscale ultrasound.

View Article and Find Full Text PDF

Purpose: The present study comparatively evaluates the performance of conventional Doppler ultrasound and superb microvascular imaging (SMI) in delineating the cortical microvessels of the transplanted kidney and compares the chronic allograft damage index (CADI) based on the examination of biopsy specimens with Doppler ultrasound and SMI findings.

Methods: Sixty-eight renal transplant recipients underwent kidney biopsy with the pre-diagnosis of rejection before undergoing renal Doppler ultrasound examination between January 2020 and October 2020. The distance between the kidney capsule and the vascular structure closest to the kidney capsule was measured at the level of the lower pole in the transplanted kidney using color Doppler ultrasound (CDUS), power Doppler ultrasound (PDUS), and the SMI technique.

View Article and Find Full Text PDF

Value of Artificial Neural Network Ultrasound in Improving Breast Cancer Diagnosis.

Comput Intell Neurosci

August 2022

Department of Medical, Hunan Polytechnic of Environment and Biology, Hengyang 421000, Hunan, China.

Ultrasound-guided needle biopsy based on artificial neural network, as a safe, effective, and simple preoperative pathological diagnosis technique, has been widely used in clinical practice. Ultrasound-guided needle biopsy based on artificial neural networks for suspicious breast lesions found in conventional ultrasound examinations is an effective method for preoperative diagnosis. The purpose of this article is to study the value of artificial neural network ultrasound in improving breast cancer diagnosis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!