Influence of multiple stenoses on echo-Doppler functional diagnosis of peripheral arterial disease: a numerical and experimental study.

Ann Biomed Eng

Laboratory of Biomedical Engineering, Institut de Recherches Cliniques de Montréal, Montréal, Québec,, Canada.

Published: April 2006

AI Article Synopsis

Article Abstract

The objective of this paper was to evaluate the ability of the peak systolic velocity ratio (PSVR) and pressure drop (DeltaP) to detect and grade multiple stenoses in lower limb mimicking arteries. Numerical simulations and experiments in vascular phantoms allowing ultrasound duplex scanning and pressure measurements were used to investigate simple and double stenotic arterial segments. Inter-stenotic distance, severity of the distal stenosis, flow rate and flow profile (steady or pulsatile) were the tested parameters. The three-dimensional simulations considered the turbulent two-equation Wilcox model. Agreements were observed between the experimental and numerical results for DeltaP and PSVR. The maximum PSVR along the artery was shown to be mainly influenced by the severity of the most important stenosis. However, mutual interactions of both stenoses on hemodynamics were noted. By using the clinical PSVR threshold used to diagnose critical lesions (PSVR > or = 2), its longitudinal evolution along the artery poorly reflected the length of the lesion or the impact of surrounding stenoses. This investigation confirms the interaction between adjacent stenoses on hemodynamics and its impact on the Doppler ultrasound index PSVR.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10439-005-9071-7DOI Listing

Publication Analysis

Top Keywords

multiple stenoses
8
stenoses hemodynamics
8
psvr
6
stenoses
5
influence multiple
4
stenoses echo-doppler
4
echo-doppler functional
4
functional diagnosis
4
diagnosis peripheral
4
peripheral arterial
4

Similar Publications

Ringed esophagus: all that glitters is not gold.

Rev Gastroenterol Peru

January 2025

Universidad Peruana Cayetano Heredia, Lima, Perú.

We report the case of an elderly patient with progressive dysphagia to solids and later to liquids, and weight loss. The patient underwent an upper endoscopy, which showed multiple stenoses and trachealization. Biopsies were taken and a diagnosis of lymphocytic esophagitis was made.

View Article and Find Full Text PDF

Diagnosis and treatment of pediatric arterial stenosis associated with neurofibromatosis type 1.

BMC Pediatr

January 2025

Department of Orthopedics, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, No.56, Nanlishi Road, Beijing, 100045, China.

Background: Neurofibromatosis type 1 (NF1) is an autosomal dominant genetic disorder affecting multiple systems. However, arterial stenosis is a rare manifestation in patients with NF1. Since the symptoms of arterial stenosis caused by NF1 are often atypical and have a high under-diagnosis rate, this can lead to serious complications such as hypertension, ischemic stroke, or even death.

View Article and Find Full Text PDF

Background: Middle cerebral artery (MCA) stenosis affects lenticulostriate arteries (LSAs) that supply the basal ganglia. Increased spatial resolution and signal-to-noise ratio of 7 T could facilitate morphological imaging of very-small-diameter LSAs.

Purpose: To evaluate differences in morphological characteristics of LSA among different MCA stenoses.

View Article and Find Full Text PDF

Background: Tyrosine kinase inhibitors (TKIs) improve prognosis in chronic myeloid leukemia (CML). Nilotinib and ponatinib, second- and third-generation TKIs, respectively, have been reported to cause adverse vascular occlusive events such as myocardial infarction and peripheral arterial disease. However, little is known about the risk of cerebral infarction associated with severe cerebrovascular stenosis, which is a late complication of TKIs.

View Article and Find Full Text PDF

Background: Quantitative flow ratio (QFR) and FFRangio are angiography-based technologies used to perform functional assessment of coronary lesions from angiographic images, validated across multiple clinical studies. There is limited information on the learning curves associated with each technology.

Aims: This study aims to compare the learning curves of QFR and FFRangio in evaluating coronary stenoses, focusing on changes in analysis speed and accuracy compared to invasive measurements.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!