Purpose: To assess in vivo the corneal epithelial damage caused by a topical toxic medication using a 60-MHz ultrasound device.
Material: and methods: A solution of timolol with 0.01% benzalkonium chloride (BAC) was applied twice a day in the test eyes of ten rabbits, and a BAC-free solution of timolol in the control eyes, for 56 days. We used a 60-MHz ultrasound device to evaluate the epithelial damage in BAC-exposed eyes, compared to control eyes. The clinical and ultrasound examinations were performed every week, and the histological analysis at the end of the experiment.
Results: The clinical findings were conjunctival redness, corneal staining and instability of the tear film. In vivo VHF ultrasound revealed a thinning of the epithelium of test eyes (from 40.9+/-1,6 microm at D0 to 31.8+/-3.4 microm at D56; p=0.0006 for D0 vs D56), while the epithelium of control eyes remained unchanged. Ultrasound epithelial thickness was correlated with corneal staining (at D34 and D56; p=0.0025 and 0.0377, respectively) and histological epithelial pachymetry (p=0.0176 for control and 0.0505 for tested epithelium). Moreover, we report qualitative VHF ultrasound imaging of early epithelial damage.
Conclusion: This new device could be very useful in ocular toxicity evaluation as a reproducible and reliable tool for multicentric clinical research.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0181-5512(06)73741-x | DOI Listing |
Acta Ophthalmol
January 2025
Neuropsychiatric Epidemiology Unit, Department of Psychiatry and Neurochemistry, Institute of Neuroscience and Physiology, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
Purpose: To explore the potential correlation between subjective and measured visual function, as well as to analyse the influence of eye disease, socioeconomic factors and emotional dimensions.
Methods: Semi-structured interviews, physical examinations and functional tests (n = 1203). Demographics covered sex, marital status, education, household economy, smoking and alcohol.
Introduction: Lotilaner ophthalmic solution (0.25%) is the first United States Food and Drug Administration (US FDA)-approved drug for treating Demodex blepharitis. In pivotal trials, it was found to be well tolerated and demonstrated a significant reduction in collarettes and mite density after a 6-week treatment regimen.
View Article and Find Full Text PDFInvest Ophthalmol Vis Sci
January 2025
Affiliated Eye Hospital of Nanchang University, Jiangxi Research Institute of Ophthalmology and Visual Science, Jiangxi Provincial Key Laboratory for Ophthalmology, Jiangxi Clinical Research Center for Ophthalmic Disease, Nanchang, China.
Purpose: This study aimed to investigate the role of SIRT4 in retinal protection, specifically its ability to mitigate excitotoxic damage to Müller glial cells through the regulation of mitochondrial dynamics and glutamate transporters (GLASTs).
Methods: A model of retinal excitatory neurotoxicity was established in mice. Proteins related to mitochondrial dynamics, GLAST, and SIRT4 were analyzed on days 0, 1, 3, and 5 following toxic injury.
Am J Physiol Heart Circ Physiol
January 2025
Vascular Biology Center and Department of Medicine, Medical College of Georgia at Augusta University, Augusta, GA USA.
The contribution of sex hormones to cardiovascular disease, including arterial stiffness, is established; however, the role of sex chromosome interaction with sex hormones, particularly in women, is lagging. Arterial structural stiffness depends on the intrinsic properties and transmural wall geometry that comprise a network of cells and extracellular matrix (ECM) proteins expressed in a sex-dependent manner. In this study, we used four-core genotype (FCG) mice to determine the relative contribution of sex hormones versus sex chromosomes or their interaction with arterial structural stiffness.
View Article and Find Full Text PDFClin Chem Lab Med
January 2025
Department of Nephrology, Ghent University Hospital Ghent, Belgium.
Objectives: We evaluated the performance of a novel flow cell morphology analyzer AUTION EYE AI-4510 for counting particles in urine.
Methods: Analytical performance was assessed according to the EFLM European Urinalysis Guideline 2023. Trueness was compared by analyzing 1.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!