Background: Ventricular tachyarrhythmias long enough to cause implantable cardioverter defibrillator (ICD) shocks are generally thought to progress to cardiac arrest. In previous ICD trials, shocks have been considered an appropriate surrogate for sudden cardiac death (SCD) because the number of shocks has been thought to be equivalent to the mortality excess in patients without ICDs. The practice of equating ICD shocks with mortality is controversial and has not been validated critically.
Methods And Results: The Defibrillators in Non-Ischemic Cardiomyopathy Treatment Evaluation (DEFINITE) trial was a prospective, randomized, multicenter trial of ICD therapy in 458 patients with nonischemic cardiomyopathy. Patients were randomized to receive standard medical therapy (STD) or STD plus an ICD. Shock electrograms were reviewed, and the cause of death was evaluated by a separate blinded events committee. There were 15 SCD or cardiac arrests in the STD group and only 3 in the ICD arm. In contrast, of the 229 patients randomized to an ICD, 33 received 70 appropriate ICD shocks. Patients in the ICD arm were more likely to have an arrhythmic event (ICD shock plus SCD) than patients in the STD arm (hazard ratio 2.12, 95% CI 1.153 to 3.893, P=0.013). The number of arrhythmic events when one includes syncope as a potential arrhythmic event was similar in both groups (hazard ratio 1.20, 95% CI 0.774 to 1.865, P=0.414). Approximately the same number of total events was noted in each arm when we compared syncope plus SCD/cardiac arrest in the STD arm with SCD plus ICD shocks plus syncope in the ICD arm.
Conclusions: Appropriate ICD shocks occur more frequently than SCD in patients with nonischemic cardiomyopathy. This suggests that episodes of nonsustained ventricular tachycardia frequently terminate spontaneously in such patients.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1161/CIRCULATIONAHA.105.561571 | DOI Listing |
Front Cardiovasc Med
December 2024
Department of Paediatrics and Adolescent Medicine, The University of Hong Kong, Pok Fu Lam, Hong Kong SAR, China.
Background: Catecholaminergic polymorphic ventricular tachycardia (CPVT) is a rare inherited arrhythmia disorder characterized by ventricular arrhythmia triggered by adrenergic stimulation.
Case Presentation: A 9-year-old boy presented with convulsions following physical exertion. Bidirectional ventricular tachycardia (VT) during a treadmill test led to the diagnosis of catecholaminergic polymorphic ventricular tachycardia (CPVT).
BMJ Support Palliat Care
December 2024
Wolfson Palliative Care Research Centre, University of Hull, Hull, UK.
Implantable cardioverter defibrillators (ICDs) are implanted in increasing numbers of patients with the aim of treating ventricular arrhythmias in high-risk patients and reducing their risk of dying. Individuals are also living longer with these devices. As a result, a greater number of patients with an ICD will deteriorate either with worsening cardiac failure, another non-cardiac condition or general frailty and will have a limited prognosis.
View Article and Find Full Text PDFJ Cardiovasc Dev Dis
December 2024
Institute of Cardiovascular Sciences, University of Birmingham, Birmingham B15 2TT, UK.
Background Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a rare genetic disorder associated with an elevated risk of life-threatening arrhythmias and progressive ventricular impairment. Risk stratification is essential to prevent major adverse cardiac events (MACE). Our study aimed to investigate the incremental value of strain measured by two-dimensional speckle-tracking echocardiography in predicting MACE in ARVC patients compared to conventional echocardiographic parameters.
View Article and Find Full Text PDFJ Cardiovasc Dev Dis
December 2024
Cardiac Electrophysiology Division, Cardiology Center, Department of Internal Medicine, University of Szeged, 6725 Szeged, Hungary.
Background: An atrioventricular defibrillator system with a floating atrial dipole (VDD ICD) can provide atrial sensing by a single lead. Our aim was to compare the arrhythmia detection efficacy of VDD ICDs with conventional single- (VVI) and dual-chamber (DDD) defibrillators.
Methods: Data from consecutive patients undergoing ICD implantation were retrospectively analyzed.
Adv Mater
December 2024
School of Biomedical Engineering, Sichuan University, Chengdu, 610065, China.
Stubborn biofilm infections pose serious threats to public health. Clinical practices highly rely on mechanical debridement and antibiotics, which often fail and lead to persistent and recurrent infections. The main culprits are 1) persistent bacteria reviving, colonizing, and rejuvenating biofilms, and 2) secondary pathogen exposure, particularly in individuals with chronic diseases.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!