The purpose of this study was to determine the thyroid, sternum and hand radiation doses of radiologists who perform angiographies and angioplasties via the radial artery. Staff radiation dose was estimated for 21 cardiac interventional catheterisations. Thermoluminescence dosemeters (TLDs) were used to determine radiation dose for each procedure at the right and left wrist, at the sternum and the thyroid. A dose area product (DAP) meter was also attached to give a direct value in Gy cm2 for each procedure. Staff radiation doses varied between 34 and 235 microGy per procedure at the left wrist, 28 and 172 microGy at the right wrist, 16 and 106 microGy at the level of the thyroid and 16 and 154 microGy at the level of the sternum. The DAP values varied between 25 and 167 Gy cm2. Radiation doses in this study are comparable to those reported in previous studies. Moreover, good correlation was found between the DAP values and the occupational dose measured with TLDs.

Download full-text PDF

Source
http://dx.doi.org/10.1093/rpd/nci763DOI Listing

Publication Analysis

Top Keywords

radiation doses
12
radial artery
8
staff radiation
8
radiation dose
8
procedure left
8
left wrist
8
microgy level
8
dap values
8
radiation
6
investigation occupational
4

Similar Publications

Background: Hypothyroidism is a common sequela after radiotherapy for nasopharyngeal carcinoma (NPC). Magnetic resonance imaging (MRI) has gained prominence in thyroid imaging, leveraging its non-ionizing radiation, high spatial resolution, multiparameter and multidirectional imaging. Few previous studies have investigated the evaluation of radiation-induced thyroid injury by MRI.

View Article and Find Full Text PDF

This study aimed to investigate the impact of X-ray irradiation pretreatment at varying doses (0.5, 1.0, 1.

View Article and Find Full Text PDF

Objectives: This study aimed to evaluate the feasibility and accuracy of non-electrocardiogram (ECG)-triggered chest low-dose computed tomography (LDCT) with a kV-independent reconstruction algorithm in assessing coronary artery calcification (CAC) degree and cardiovascular disease risk in patients receiving maintenance hemodialysis (MHD).

Methods: In total, 181 patients receiving MHD who needed chest CT and coronary artery calcium score (CACS) scannings sequentially underwent non-ECG-triggered, automated tube voltage selection, high-pitch chest LDCT with a kV-independent reconstruction algorithm and ECG-triggered standard CACS scannings. Then, the image quality, radiation doses, Agatston scores (ASs), and cardiac risk classifications of the two scans were compared.

View Article and Find Full Text PDF

Ionizing radiation exposure during perinatal development can produce various biological effects on the developing offspring. These effects are dependent on a number of factors, including total dose, dose rate and the developmental processes occurring at the time of irradiation. The present study conducted an analysis of historical radiobiological archived data involving 60Co-gamma irradiation of beagle dogs at specific periods of prenatal or postnatal development.

View Article and Find Full Text PDF

Assessment of the effectiveness of Monte Carlo Simulation for dose control at the Moroccan Boukhalef ionization facility.

Appl Radiat Isot

January 2025

Department of Physics, Nuclear Physics and Techniques Team, Faculty of Science, Ibn Tofail University, Kenitra, Morocco.

Controlling the absorbed dose received by a target is a major challenge encountered during ionizing radiation applications. For experimentally measuring absorbed dose, dosimetric systems are used. On the other hand, in addition to experimental methods of dose measurement, there are other alternatives for calculating absorbed doses, these are numerical methods based on the Monte Carlo method which are very sophisticated and widely used throughout the world.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!