Long-term evaluation of hollow screw and hollow cylinder dental implants: clinical and radiographic results after 10 years.

J Periodontol

Department of Oral-Maxillofacial Surgery and Maxillofacial Prosthetics, Faculty of Medical Sciences, University Medical Center Groningen, Groningen, The Netherlands.

Published: February 2006

Background: In 1988, an implant manufacturer offered a new dental implant system, with a wide choice of hollow cylinder (HC) and hollow screw (HS) implants. The purpose of this retrospective study of HS and HC implants was to evaluate clinical and radiographic parameters of peri-implant tissue and to analyze surgical and prosthetic aftercare.

Methods: A total of 89 HS and 26 HC implants in 38 edentulous patients were available for complete evaluation. The patients were treated with overdentures stabilized by two or four implants. The follow-up period was 10 years.

Results: The results of the clinical evaluation showed a mean sulcus probing depth of 3.3+/-1.3 mm (range=2 to 10 mm). The mean radiographic bone loss was 2.2+/-2.1 mm (range=0.1 to 12.2 mm). One implant (HS) was removed during the osseointegration period. Three other implants (two HS and one HC) in three patients had to be removed after 10 years. The survival rate of the HS implant (96.6%) was comparable to the HC implant (96.1%). The success rate of the HS implant (93.3%) was slightly more favorable compared to the HC implant (88.5%). The HS and HC implants met the Albrektsson criteria of success.

Conclusions: HS and HC implants provide a stable base for long-term support of a mandibular overdenture. Furthermore, it is important to monitor peri-implant bone level by taking annual radiographs and measuring probing depth, especially after prolonged service.

Download full-text PDF

Source
http://dx.doi.org/10.1902/jop.2006.040346DOI Listing

Publication Analysis

Top Keywords

hollow screw
8
hollow cylinder
8
implants
8
clinical radiographic
8
probing depth
8
rate implant
8
implant
7
long-term evaluation
4
hollow
4
evaluation hollow
4

Similar Publications

In a slim-floor structural system, beams and slabs are placed at the same level, reducing the overall floor height and material usage in vertical structures, thereby improving economic efficiency. The use of slim-floor structures is common practice in Finnish construction where these structures are typically constructed using hollow-concrete slabs and welded steel box beams. However, in Finland, only a few buildings utilise cross-laminated timber (CLT) slabs in slim-floor structures, and none have incorporated the composite action between CLT and steel beams.

View Article and Find Full Text PDF

Objectives: The study aimed to evaluate the efficacy and safety of hollow pedicle screw-anchored bone cement combined with posterior long-segment fixation (LSF) for the treatment of Stage III Kümmell's disease.

Patients And Methods: The study retrospectively analyzed 23 patients (18 females, 5 males; mean age: 70.1±6.

View Article and Find Full Text PDF

Background: Vertebral augmentation is the preferred treatment for Kümmell disease (KD), but there exists a risk of cement displacement resulting in severe back pain and exacerbation of kyphosis. The study aimed to investigate the efficacy and safety of a novel hollow pedicle screw combined with kyphoplasty (HPS-KP) for treating KD, effectively preventing postoperative bone cement displacement.

Methods: The prospective study included 50 KD patients with no neurological deficit detected during clinical and radiological evaluation who underwent HPS-KP ( = 25) and PKP ( = 25) surgeries.

View Article and Find Full Text PDF

Background: The management of Garden IV femoral neck fractures presents a formidable challenge. This study aimed to assess the safety and efficacy of a novel technological approach for treating Garden IV femoral neck fractures, involving intracapsular decompression and the utilization of supported hollow screws.

Methods: Between October 2018 and October 2021, a cohort of 46 patients, comprising 25 males and 21 females, was admitted for Garden IV femoral neck fractures.

View Article and Find Full Text PDF

Purpose: To explore the percutaneous minimally invasive treatment of pubic symphysis and its adjacent fractures.

Method: Since May 2021, 13 cases of fractures involving the pubic symphysis and its adjacent parts were treated with x-ray fluoroscopic localization and percutaneous cannulated screw fixation across the symphysis pubis, the guide pin pierced the symphysis pubis and the fracture end and stopped at the inner edge of the acetabulum. Visual analogue scale (VAS) was used to evaluate the effect of the operation, and the patients were followed up.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!