We present a rare case of spontaneous rupture of the adductor longus tendon induced by ciprofloxacin. A 35-year-old man was diagnosed with pneumonia and was recommended ciprofloxacin 500 mg iv twice a day for 7 days. Three days after receiving the initial dose, he developed discomfort in his left medial thigh, and pain and swelling in the same area followed ten days later. He consulted us when he noted a palpable mass on the medial side of his left thigh, and MRI study revealed adductor longus tendon rupture. There was no obvious underlying disease or other factor causing fragility of his adductor longus tendon. We review the pathophysiological mechanisms leading to fluoroquinolone-related tendon rupture as well as the risk factors and discuss proper management.

Download full-text PDF

Source

Publication Analysis

Top Keywords

adductor longus
16
longus tendon
16
rupture adductor
8
tendon rupture
8
tendon
5
rupture
4
longus
4
tendon ciprofloxacin
4
ciprofloxacin rare
4
rare case
4

Similar Publications

This study aimed to evaluate the muscle activation ratio of hip and knee during hip-focused exercises. Eleven active university students performed 13 hip-focused exercises frequently used in the treatment of knee disorders. The average sEMG amplitude of tensor fasciae latae (TFL), gluteus medius (GMed), gluteus maximus (GMax), adductor longus (AL), vastus medialis (VM), vastus lateralis (VL), and GMed/AL, GMax/AL, and VL/VM ratios were determined.

View Article and Find Full Text PDF

Background: This study investigates a novel isometric method utilizing an external focus instruction technique with a soft paper balloon. By emphasizing control to avoid crushing the balloon, this method promotes co-contraction of muscles without exerting pressure on the object. We aim to evaluate differences in muscle activation patterns during isometric hip abduction exercises between the paper balloon task and tasks using external resistance (hard plastic, non-elastic, and elastic bands), and further determine their influence on the contralateral side.

View Article and Find Full Text PDF

The purpose of this study was to compare maximal adduction (ADD) and abduction (ABD) force, ADD to ABD ratio (ADD:ABD), inter-limb asymmetries and muscle activity between five isometric hip strength assessment positions. Twenty male athletes performed the following positions: seated (SE), supine at knees with 0° hip flexion (SK) and 45° hip flexion (SK), and supine at ankles bilaterally (SA) and unilaterally (SA). Normalised muscle activity (%EMG) of adductor longus (ADD), gracilis (GRAC), gluteus medius (G), sartorius (SAR), and lower rectus abdominis (REC) were also assessed.

View Article and Find Full Text PDF

The Genitofemoral Nerve Is the Structure Closest to the Tendon Footprint and Is Most at Risk for Iatrogenic Injury During Proximal Adductor Longus Repair: A Cadaveric Anatomy Study.

Arthrosc Sports Med Rehabil

October 2024

Section of Young Adult Hip Surgery, Division of Sports Medicine, Department of Orthopedic Surgery, Rush Medical College of Rush University, Rush University Medical Center, Chicago, Illinois, U.S.A.

Purpose: To identify structures at risk during proximal adductor longus repair and to report observed distances between these structures and the adductor longus (AL) footprint.

Methods: Eight hemipelves from fresh cadaver whole-body specimens were dissected using a previously established surgical approach. The tendinous attachment of the AL was scored into the underlying bone and the footprint size was measured in millimeters.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!