AI Article Synopsis

Article Abstract

A diamagnetic particle with magnetic susceptibilities chi3 < chi2 = chi1 < 0 was subjected to a rotating magnetic field to obtain an alignment of the chi3 axis (the smallest susceptibility axis) in the direction perpendicular to the plane of the rotating magnetic field. A polymer short fiber, whose fiber axis coincides with the chi3 axis, was suspended in a fluid with the same density, and then a rotating magnetic field generated by a rotation of a pair of permanent magnets was applied. The fiber axis, rotating following the applied field, finally ended up with an alignment perpendicular to the plane of the rotating magnetic field. The experimental data on the time course of the alignment was in good agreement with the numerical calculation based on the equation of rotation.

Download full-text PDF

Source
http://dx.doi.org/10.1021/la049347wDOI Listing

Publication Analysis

Top Keywords

rotating magnetic
16
magnetic field
16
susceptibility axis
8
chi3 axis
8
perpendicular plane
8
plane rotating
8
fiber axis
8
axis
6
magnetic
6
rotating
5

Similar Publications

Unconventional spin-orbit torques arising from electric-field-generated spin currents in anisotropic materials have promising potential for spintronic applications, including for perpendicular magnetic switching in high-density memory applications. Here, all the independent elements of the spin torque conductivity tensor allowed by bulk crystal symmetries for the tetragonal conductor IrO are determined via measurements of conventional (in-plane) anti-damping torques for IrO thin films in the high-symmetry (001) and (100) orientations. It is then tested whether rotational transformations of this same tensor can predict both the conventional and unconventional anti-damping torques for IrO thin films in the lower-symmetry (101), (110), and (111) orientations, finding good agreement.

View Article and Find Full Text PDF

Miniaturized inertial sensor based on high-resolution dual atom interferometry.

Rev Sci Instrum

January 2025

State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences, Wuhan 430071, China.

Atom interferometry shows high sensitivity for inertial measurements in the laboratory, but it faces difficulties in field applications because of a trade-off between sensitivity and size. Therefore, there is an urgent need to develop a small sensor with high resolution for measuring acceleration and rotation in inertial navigation applications. Presented here is a miniaturized inertial sensor capable of measuring acceleration and rotation simultaneously based on high-resolution dual atom interferometers.

View Article and Find Full Text PDF

Background: Magnetic resonance imaging (MRI) measurement parameters-the standard noninvasive diagnostic method for rotator cuff tears (RCTs)-have been used to compare groups with and without RCTs. Arthroscopy is used in definitive diagnosis and treatment.

Purposes: To evaluate the association between RCT and shoulder angles and distances on MRI in patients with and without arthroscopically validated RCT and to determine whether the degree of rotator cuff fatty degeneration affects the MRI measurements.

View Article and Find Full Text PDF

The purpose of this study was the detection and characterization of synergistic muscle activity. Using T-map MRI, T values for 10 forearm muscles in 11 healthy adult volunteers were obtained in the resting state and after isotonic forearm supination and pronation exercises with the elbow extended. T was normalized by Z = (T-T)/SD, where T was T after exercise, while T and SD were the reference values of 34 ms and 3 ms, respectively.

View Article and Find Full Text PDF

Accessory posterior cerebral artery as a duplicate anterior choroidal artery.

Surg Radiol Anat

January 2025

Department of Neurosurgery, Nakamura Memorial Hospital, South 1, West 14, Chuo-ku, Sapporo, Hokkaido, 060-8570, Japan.

Purpose: Anatomical variations in the anterior choroidal artery (AChA) and/or the posterior cerebral artery (PCA) are rare. Hyperplastic AChA is an anatomical variant supplying both the AChA area and the PCA area. In accessory PCA, a hyperplastic AChA supplies part of the PCA territory.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!