Purpose Of The Study: To develop a finite element model (FEM) to study the effect of the stress and strain, in microvascular anastomoses that result from the geometrical mismatch of anastomosed vessels.
Material And Methods: FEMs of end-to-end and end-to-side anastomoses were constructed. Simulations were made using finite element software (NISA). We investigated the angle of inset in the end-to-side anastomosis and the discrepancy in the size of the opening in the vessel between the host and recipient vessels. The FEMs were used to predict principal and shear stress and strain at the position of each node.
Results: Two types of vascular deformation were predicted during different simulations: longitudinal distortion, and rotational distortion. Stress values ranged from 151.1 to 282.4MPa for the maximum principal stress, from -122.9 to -432.2MPa for the minimum principal stress, and from 122.1 to 333.1MPa for the maximum shear stress. The highest values were recorded when there was a 50% mismatch in the diameter of the vessels at the site of the end-to-end anastomosis.
Conclusion: The effect of the vessel's size discrepancy on the blood flow and deformation was remarkable in the end-to-end anastomosis. End-to-side anastomosis was superior to end-to-end anastomosis. FEM is a powerful tool to study vascular deformation, as it predicts deformation and biomechanical processes at sites where physical measurements are likely to remain impossible in living humans.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.bjoms.2005.11.022 | DOI Listing |
Sci Rep
January 2025
Department of Orthopedics, Honghui Hospital, Xi'an Jiaotong University, Xi'an, 710054, Shaanxi, China.
The best treatment method for reverse obliquity intertrochanteric fractures (ROIFs) is still under debate. Our team designed the modified proximal femoral nail (MPFN) specially for treating such fractures. The objective of this research was to introduce the MPFN device and compare the biomechanical properties with Proximal Femoral Nail Antirotation (PFNA) and InterTAN nail via finite element modelling.
View Article and Find Full Text PDFUltrasonics
January 2025
School of Information Science and Technology, Beijing University of Technology, Beijing 100124 China.
Carbon steel and low alloy steel are pearlitic heat-resistant steels with a lamellar microstructure. There are good mechanical properties and are widely used in crucial components of high-temperature pressure. However, long-term service in high-temperature environments can easily lead to material degradation, including spheroidization, graphitization, and thermal aging.
View Article and Find Full Text PDFJ Chromatogr A
January 2025
Institute for Bioengineering, School of Engineering, The University of Edinburgh, Edinburgh, EH9 3BF, United Kingdom.
Traditional packed beds in chromatography suffer from increased band broadening due to the random nature of packing, leading non-ideal fluid flow and channeling. To address these challenges, pillar array columns have been developed, offering improved performance over random packing thanks to their homogenous fluid profiles. The study aims to i) evaluate fluid dynamics and chromatographic performance across different PAC morphologies, ii) establish the influence of column morphology on performance, and iii) assess the correlation between chromatographic performance and hydrodynamic parameters.
View Article and Find Full Text PDFComput Methods Biomech Biomed Engin
January 2025
Key Laboratory of Advanced Design and Simulation Techniques for Special Equipment, Ministry of Education, Hunan University, Changsha, China.
Total talus replacement has been demonstrated to increase ankle instability. However, no studies have explored how to enhance postoperative stability. This study aims to explore the effect of collateral ligament reconstruction on ankle stability by finite element analysis.
View Article and Find Full Text PDFPharmaceutics
January 2025
Department of Mathematical and Physical Sciences, Catholic University of Temuco, Temuco 4813302, Chile.
: A previous study investigated the in vitro release of methylene blue (MB), a widely used cationic dye in biomedical applications, from nanocellulose/nanoporous silicon (NC/nPSi) composites under conditions simulating body fluids. The results showed that MB release rates varied significantly with the nPSi concentration in the composite, highlighting its potential for controlled drug delivery. To further analyze the relationship between diffusion dynamics and the MB concentration, this study developed a finite element (FE) method to solve Fick's equations governing the drug delivery system.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!