A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Minimally invasive sentinel lymph node mapping of the pig colon with Lymphoseek. | LitMetric

Background: Minimally invasive surgery and sentinel node mapping are being utilized increasingly in colon cancer surgery. Making these techniques efficient and easy to perform will be essential for the future of this and other gastrointestinal operations. The purpose of this study was to test a new laparoscopic gamma detection probe for minimally invasive sentinel node mapping of the colon, while utilizing Lymphoseek, a radiopharmaceutical specifically designed for sentinel lymph node (SLN) detection.

Methods: Eight anesthetized pigs received an endoscopic co-injection of Lymphoseek and Isosulfan Blue in the colon. The laparoscopic gamma detector, inserted via a 12-mm trocar, was used to identify radioactive sentinel lymph nodes. The reliability of the side-viewing probe was tested using a radioactive source. All blue and radioactive lymph nodes were excised and the signal-to-background ratio (S/B) and percent of injected dose (%ID) were measured.

Results: The probe was easy to maneuver and led to efficient visualization of the radioactive node. The side port allowed for better distinction between injection site scatter and sentinel node activity. The reliability of the probe was validated by an identification rate of 97%. At least one SLN was detected for each pig; two SLNs were detected in two pigs. All SLNs were stained blue. The SLN S/B ranged from 38 to 315 and the %ID ranged from 0.06% to 2.01%. Sentinel nodes were found within 10 minutes.

Conclusions: Minimally invasive sentinel node mapping with the radiopharmaceutical Lymphoseek and a side-viewing gamma detector yielded high S/B and directionality for accurate mapping of gastrointestinal sentinel lymph nodes within minutes of radiotracer administration.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.surg.2005.06.038DOI Listing

Publication Analysis

Top Keywords

minimally invasive
16
sentinel lymph
16
node mapping
16
sentinel node
16
invasive sentinel
12
lymph nodes
12
sentinel
9
lymph node
8
laparoscopic gamma
8
gamma detector
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!