This study on the relationships of indoor, outdoor, and personal air (RIOPA) was undertaken to collect data for use in evaluating the contribution of outdoor sources of air toxics and particulate matter (PM) to personal exposure. The study was not designed to obtain a population-based sample, but rather to provide matched indoor, outdoor, and personal concentrations in homes that varied in their proximity to outdoor pollution sources and had a wide range of air exchange rates (AERs). This design allowed examination of relations among indoor, outdoor, and personal concentrations of air toxics and PM across a wide range of environmental conditions; the resulting data set obtained for a wide range of environmental pollutants and AERs can be used to evaluate exposure models. Approximately 100 households with residents who do not smoke participated in each of three cities in distinct locations expected to have different climates and housing characteristics: Elizabeth, New Jersey; Houston, Texas; and Los Angeles County, California. Questionnaires were administered to characterize homes, neighborhoods, and personal activities that might affect exposures. The concentrations of a suite of volatile organic compounds (VOCs) and carbonyl compounds, as well as the fraction of airborne particulate matter with a mass median aerodynamic diameter < or = 2.5 microm (PM2.5), were measured during continuous 48-hour sessions in which indoor, outdoor, and personal air samples were collected simultaneously. During the same 48-hour period, the AER (exchanges/hr; x hr(-1)) was determined in each home, and carbonyl compounds were measured inside vehicle cabins driven by a subset of the participants. In most of the homes, measurements were made twice, during two different seasons, to obtain a wide distribution of AERs. This report presents in detail the data collection methods, quality control measures, and initial analyses of data distributions and relations among indoor, outdoor, and personal concentrations. The results show that indoor sources dominated personal and indoor air concentrations of many measured VOCs and carbonyl compounds. For several measured species, personal concentrations were higher than either indoor or outdoor concentrations, indicating the presence of some sources closely related to personal activities. For some species there were no significant indoor sources in the majority of the homes; thus indoor concentrations were mainly determined by outdoor concentrations in these homes. The range of distributions of air concentrations for the measured VOCs, formaldehyde and acetaldehyde, PM2.5, and AERs were generally consistent with values reported previously in the literature. Thus associations derived from or models based on this data set that may link the influence of outdoor sources with indoor air concentrations of air toxics and PM2.5 can be relevant to other urban settings. The simultaneous measurements of indoor concentrations, outdoor concentrations, AERs, and room volumes allowed the use of a mass balance model, under the steady-state approximation, to mechanistically examine the relative contributions of indoor and outdoor sources to measured indoor concentrations on a home-by-home basis. Estimated indoor source strengths for VOCs and carbonyl compounds varied widely from home to home, consistent with the indoor-outdoor concentration patterns, as shown in scatter plots. The indoor source estimations agreed with published values for PM2.5 and with the general understanding of sources of VOCs and carbonyl compounds. The source strengths reported here, derived from hundreds of homes, are an important contribution to the literature on exposure to air toxics. For the first time for many compounds, these estimates present a cohesive set of measurements across a range of air toxics in paired indoor, outdoor, and personal samples along with AER and questionnaire results that can be used for future analyses of indoor air quality. The estimation of outdoor contributions to measured indoor concentrations provides insights about the relative importance of indoor and outdoor sources in determining indoor concentrations, the main determinant of personal exposure for most of the measured compounds. In this report simple statistical tests mainly of the pooled data were used to analyze differences by sampling site, emission source type, season, home type, and home age. Paired adult-child personal concentrations within the same home were also compared using the pooled data set. These analyses generated some intriguing results that warrant more in-depth investigation in the future.
Download full-text PDF |
Source |
---|
J Urban Health
January 2025
Department of Geography, Florida State University, Bellamy Building, Room 323, 113 Collegiate Loop, PO Box 3062190, Tallahassee, FL, 32306-2190, USA.
Understanding when and where heat adversely influences health outcomes is critical for targeting interventions and adaptations. However, few studies have analyzed the role of indoor heat exposures on acute health outcomes. To address this research gap, the study partnered with the New York City Fire Department Emergency Medical Services.
View Article and Find Full Text PDFCurr Opin Allergy Clin Immunol
January 2025
Department of Pulmonology, Allergy and Thoracic Oncology, University Hospital of Montpellier, Montpellier, France.
Purpose Of Review: Climate change influences working conditions in various ways, affecting employee health and safety across different sectors. Climatic factors like rising temperatures, increased UV radiation, and more frequent extreme weather events pose risks to in both indoor and outdoor workers. Allergic diseases of the respiratory tract and the skin may emerge due to climate change.
View Article and Find Full Text PDFPlant Cell Environ
January 2025
Institute of Organismic and Molecular Evolution, University of Mainz, Mainz, Rheinland-Pfalz, Germany.
Transgenerational plasticity in plants is an increasingly recognized phenomenon, yet it is mostly unclear whether transgenerational plasticity is relevant to both the fitness of the plant and its interacting species. Using monoclonal strains of the giant duckweed (Spirodela polyrhiza) and its native herbivore, the waterlily aphid (Rhopalosiphum nymphaeae), we assessed whether pre-treating plants with copper excess, both indoors and outdoors, induces transgenerational plasticity in plant defences that alter plant and herbivore fitness. Outdoors, copper pre-treatment tended to increase plant growth rates under recurring copper excess.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Engineering Design, KTH Royal Institute of Technology, SE-100 44 Stockholm, Sweden.
Topography estimation is essential for autonomous off-road navigation. Common methods rely on point cloud data from, e.g.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Department of Civil Engineering and Engineering Management, National Quemoy University, Kinmen 89250, Taiwan.
Ground-based LiDAR technology has been widely applied in various fields for acquiring 3D point cloud data, including spatial coordinates, digital color information, and laser reflectance intensities (I-values). These datasets preserve the digital information of scanned objects, supporting value-added applications. However, raw point cloud data visually represent spatial features but lack attribute information, posing challenges for automated object classification and effective management.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!