Reference points for radial head prosthesis size.

J Hand Surg Am

Department of Orthopaedic Surgery and Biostatistics, Harvard Medical School, and Orthopaedic Hand and Upper Extremity Service, Massachusetts General Hospital, Boston, MA 02114, USA.

Published: January 2006

Purpose: Metallic radial head implants are useful when the radial head cannot be repaired reliably and when either the elbow or the forearm is unstable. Problems arise when the radial head prosthesis is too thick, causing erosions of the capitellum and incongruity of the ulnohumeral joint. We used quantitative 3-dimensional computed tomography analysis to investigate the relative height of the radial head relative to the lateral edge and central ridge of the coronoid process as reference points for optimal insertion of a radial head prosthesis.

Methods: Seventeen computed tomography scans of the elbow were analyzed. The anatomic coronal plane of the forearm was determined using 3-dimensional images and a 2-dimensional image bisecting the articular surface of the radial head was created in this plane. The distance between the plane of the articular surface of the radial head and parallel planes at the most proximal aspect of the coronoid (the central ridge) and the lateral edge of the coronoid articular surface were measured. Negative values indicate the radial head is proximal to the coronoid.

Results: The average distance between the planes defined by the radial head articular surface and the coronoid central ridge was -0.8 mm. The average distance between the planes defined by the radial head articular surface and the lateral edge of the coronoid articular surface was -0.9 mm.

Conclusions: Because the radial head was on average only 0.9 mm more proximal than the lateral edge of the coronoid process and because the key is to not overstuff the joint a useful general guideline would be to place the plane of the articular surface of the radial head even with or just slightly more proximal than the lateral edge of the coronoid articular surface. Considering the substantial variability of the normal height of the articular surface of the radial head with respect to that of the coronoid, preoperative radiographs of the opposite elbow may be useful to avoid overstuffing the elbow.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jhsa.2005.06.012DOI Listing

Publication Analysis

Top Keywords

radial head
56
articular surface
36
lateral edge
20
surface radial
16
edge coronoid
16
radial
14
head
14
central ridge
12
coronoid articular
12
articular
9

Similar Publications

Background: We evaluated the accuracy of magnetic resonance imaging (MRI) computed tomography (CT)-like sequences compared to normal-resolution CT (NR-CT) and super-high-resolution CT (SHR-CT) for planning of cochlear implantation.

Methods: Six cadaveric temporal bone specimens were used. 3-T MRI scans were performed using radial volumetric interpolated breath-hold (STARVIBE), pointwise-encoding time reduction with radial acquisition (PETRA), and ultrashort time of echo (UTE) sequences.

View Article and Find Full Text PDF

Purpose: Diffusing alpha-emitters Radiation Therapy ("Alpha DaRT") is a new cancer treatment modality that employs radium-224-loaded metal sources implanted in solid tumors to disperse alpha-emitting atoms within a therapeutic "kill-zone" of a few millimeters around each source. Preclinical studies have demonstrated tumor growth delay in various cancer types, including glioblastoma multiforme, and the method is used in clinical trials for patients with skin and head and neck cancer. This study aims to assess the safety and feasibility of implementing Alpha DaRT for brain tumor treatment in a large animal model.

View Article and Find Full Text PDF

Fractures involving the proximal ulna and radial head are common injuries that occur in the upper extremity, often resulting from traumatic incidents such as falls or direct impact. The proximal ulna forms the elbow joint with the humerus, while the radial head articulates with both the humerus and the ulna, facilitating forearm rotation. Fractures in these areas can disrupt the stability and function of the elbow joint, leading to pain, swelling, and limited range of motion.

View Article and Find Full Text PDF

Role of Free Flaps in Facial Burn Reconstructions.

Indian J Plast Surg

December 2024

Department of Plastic and Reconstructive Surgery, Nizam's Institute of Medical Sciences, Hyderabad, Telangana, India.

Traditionally, burn reconstructions have been performed by the use of skin grafting or local flaps. Recently free flaps are being used with increasing frequency. Although not very common in the head neck region, free flaps are mostly used for secondary reconstructions of cervicofacial contractures.

View Article and Find Full Text PDF

Objective: This study explored the surgical technique and clinical application of the dorsal metacarpal cutaneous branch flap of the radial digital artery of the index finger.

Methods: Through the anatomical dissection of 10 hand specimens, we examined the origin and characteristics of the artery and its branches towards the hand dorsum. Furthermore, the soft tissue defects of the index finger in 12 patients admitted to our hospital between 2017 and 2021 were surgically repaired using the dorsal metacarpal cutaneous branch flap of the radial digital artery of the index finger.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!