We propose a new luminosity function, V*(lambda), that improves upon the original CIE 1924 V(lambda) function and its modification by D. B. Judd (1951) and J. J. Vos (1978), while being consistent with a linear combination of the A. Stockman & L. T. Sharpe (2000) long-wavelength-sensitive (L) and middle-wavelength-sensitive (M) cone fundamentals. It is based on experimentally determined 25 Hz, 2 degrees diameter, heterochromatic (minimum) flicker photometric data obtained from 40 observers (35 males, 5 females) of known genotype, 22 with the serine variant L(ser180), 16 with the alanine L(ala180) variant, and 2 with both variants of the L-cone photopigment. The matches, from 425 to 675 nm in 5-nm steps, were made on a 3 log troland xenon white (correlated color temperature of 5586 K but tritanopically metameric with CIE D65 standard daylight for the Stockman and Sharpe L- and M-cone fundamentals in quantal units) adapting field of 16 degrees angular subtense, relative to a 560-nm standard. Both the reference standard and test lights were kept near flicker threshold so that, in the region of the targets, the total retinal illuminance averaged 3.19 log trolands. The advantages of the new function are as follows: it forms a consistent set with the new proposed CIE cone fundamentals (which are the Stockman & Sharpe 2000 cone fundamentals); it is based solely on flicker photometry, which is the standard method for defining luminance; it corresponds to a central 2 degrees viewing field, for which the basic laws of brightness matching are valid for flicker photometry; its composition of the serine/alanine L-cone pigment polymorphism (58:42) closely matches the reported incidence in the normal population (56:44; Stockman & Sharpe, 1999); and it specifies luminance for a reproducible, standard daylight condition. V*(lambda) is defined as 1.55L(lambda) + M(lambda), where L(lambda) and M(lambda) are the Stockman & Sharpe L- & M-cone (quantal) fundamentals. It is extrapolated to wavelengths shorter than 425 nm and longer than 675 nm using the Stockman & Sharpe cone fundamentals.

Download full-text PDF

Source
http://dx.doi.org/10.1167/5.11.3DOI Listing

Publication Analysis

Top Keywords

stockman sharpe
24
cone fundamentals
16
function v*lambda
8
sharpe 2000
8
fundamentals based
8
standard daylight
8
sharpe m-cone
8
flicker photometry
8
stockman
6
sharpe
6

Similar Publications

Purpose: Evaluate quantitative leakage parameters on ultrawidefield fluorescein angiography (UWF-FA) images and explore their association with Diabetic Retinopathy Severity Scale (DRSS), predominantly peripheral lesions (PPLs), visual acuity, and clinical characteristics.

Design: A post hoc analysis of baseline UWF-FA images in the DRCR Retina Network observational study Protocol AA.

Participants: A total of 575 eyes from 384 adults across 38 sites in the United States and Canada with gradable UWF-FA.

View Article and Find Full Text PDF

Normal color perception is complicated. But at its initial stage it is relatively simple, since at photopic levels it depends on the activations of just three photoreceptor types: the long- (L-), middle- (M-) and short- (S-) wavelength-sensitive cones. Knowledge of how each type responds to different wavelengths-the three cone spectral sensitivities-can be used to model human color vision and in practical applications to specify color and predict color matches.

View Article and Find Full Text PDF

Importance: Anti-vascular endothelial growth factor (VEGF) injections in eyes with nonproliferative diabetic retinopathy (NPDR) without center-involved diabetic macular edema (CI-DME) reduce development of vision-threatening complications from diabetes over at least 2 years, but whether this treatment has a longer-term benefit on visual acuity is unknown.

Objective: To compare the primary 4-year outcomes of visual acuity and rates of vision-threatening complications in eyes with moderate to severe NPDR treated with intravitreal aflibercept compared with sham. The primary 2-year analysis of this study has been reported.

View Article and Find Full Text PDF

Importance: Presence of predominantly peripheral diabetic retinopathy (DR) lesions on ultra-widefield fluorescein angiography (UWF-FA) was associated with greater risk of DR worsening or treatment over 4 years. Whether baseline retinal nonperfusion assessment is additionally predictive of DR disease worsening is unclear.

Objective: To assess whether the extent and location of retinal nonperfusion identified on UWF-FA are associated with worsening in Diabetic Retinopathy Severity Scale (DRSS) score or DR treatment over time.

View Article and Find Full Text PDF
Article Synopsis
  • Ultra-widefield (UWF) imaging is more effective at finding peripheral diabetic retinopathy (DR) lesions compared to standard imaging techniques, but it remains unclear if these lesions can predict worsening disease.
  • A cohort study involving 388 participants across 37 sites was conducted to investigate if predominantly peripheral lesions (PPLs) detected by UWF imaging are linked to an increased risk of disease worsening, beyond what is indicated by initial DR severity scores.
  • After analyzing data from 544 study eyes, findings showed that rates of disease worsening varied by the severity of nonproliferative diabetic retinopathy (NPDR), but the presence of color PPL at baseline did not significantly predict worsening outcomes.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!