Purpose: The aim of our study was to assess the usefulness of positioning metal wires under ultrasound guidance for localising soft tissue lesions in the preoperative phase.

Materials And Methods: We studied superficial soft-tissue lesions in 12 patients, using hooked mammographic wires of different lengths. One patient had a multifocal growth of disease which required a double localisation procedure. Correct positioning of the wire was confirmed by ultrasonography. All patients underwent surgery within five hours of hook-wire positioning.

Results: Correct wire position was confirmed at surgery in 12 out of 13 procedures. In one case the hook-wire reached the margin of the lesion. In all cases, the preoperative localisation procedure facilitated identification and resection of the masses.

Conclusions: In our experience, the main indications for hook-wire positioning before surgery are: marking of small lesions, localisation of lesions in anatomic areas structurally subverted by previous surgery and consequently difficult to detect, guidance for surgical sectioning in order safeguard the noble structures close to the lesions.