A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Renal artery stenosis: functional assessment with dynamic MR perfusion measurements--feasibility study. | LitMetric

Renal artery stenosis: functional assessment with dynamic MR perfusion measurements--feasibility study.

Radiology

Institute of Clinical Radiology, University Hospitals-Grosshadern, Department of Internal Medicine, Division of Nephrology, Ludwig-Maximilians-University, Marchioninistrasse 15, 81377 Munich, Germany.

Published: February 2006

Purpose: To prospectively assess feasibility of renal magnetic resonance (MR) perfusion measurement method based on turbo fast low-angle shot sequences for grading effect of renal artery stenosis (RAS) on parenchymal perfusion.

Materials And Methods: Institutional review board approved this study, and patients gave written consent. Seventy-three patients (34 male, 39 female; age range, 17-84 years) who were clinically suspected of having RAS underwent contrast material-enhanced (gadodiamide) saturation-recovery turbo fast low-angle shot imaging for measurement of renal perfusion and high-spatial-resolution MR angiography for RAS detection and grading. Degree of stenosis was evaluated as high grade (>/=75% stenosis), low to intermediate grade (>0% to <75% stenosis), or absent. High temporal resolution of the turbo fast low-angle shot sequence allowed acquisition of an exact first-pass tracing of the contrast agent bolus from which a signal intensity (SI)-time curve was derived. On the basis of this curve, mean transit time (MTT) of the contrast agent bolus, maximal upslope (MUS) of the curve, maximum SI, and time to SI peak (TTP) were calculated with a gamma variate fit. Wilcoxon rank sum test, Pearson product moment correlation, and paired t test were used for statistical analysis.

Results: Twenty-four renal arteries had high-grade RAS, 12 renal arteries had low- to intermediate-grade RAS, and 104 renal arteries had no RAS. Significant differences between patients without stenoses or with low- to intermediate-grade stenoses and patients with high-grade stenoses were found for MTT, MUS, and TTP (P < .001). Perfusion parameters were correlated with patients' serum creatinine levels, and significant correlations were found for MTT (r = 0.41), MUS (r = 0.48), and TTP (r = 0.4), with P < .001.

Conclusion: MR perfusion parameters can be used to assess effect of RAS on parenchymal perfusion. Perfusion measurements reflect renal function as measured with serum creatinine levels.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.2382041553DOI Listing

Publication Analysis

Top Keywords

renal artery
8
artery stenosis
8
turbo fast
8
fast low-angle
8
low-angle shot
8
renal
4
stenosis
4
stenosis functional
4
functional assessment
4
assessment dynamic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!