Maintenance of graft compression in the adult cervical spine.

Eur Spine J

Department of Neurosurgery, Neurosurgical Research and Development Unit, Beaumont Hospital, Dublin, Ireland.

Published: August 2006

It is generally advised that the graft inserted in adult cervical spine should be pre-loaded with a compressive force or that the screws are inserted in a divergent orientation, in order to maximise compression and the chance of graft incorporation (Truumees et al. in Spine 28:1097-1102, 2003). However, there is little evidence that a compressive force is maintained once the force applicator has been removed, or that the divergent screws enhance compression. This study compared the maintenance of applied pre-load force, across cervical spine graft, between standard anterior plating technique with pre-load and divergent screws and a novel plate technique, which allows its application prior to removal of the force applicator. Six intact adult cadaveric human cervical spines were exposed by standard surgical technique. A Casper type distracter was inserted across the disc space of interest, the disc was removed. In 14 experiments, following the disc removal, an autologous iliac crest bone graft was inserted under distraction, together with a strain gauge pressure transducer. A resting output from the transducer was recorded. The voltage output has a linear relationship with compressive force. A standardised compressive force was applied across the graft through the "Casper type" distracter/compressor (7.5 kg, torque). The pre-load compressive force was measured using a torque drill. Then two different procedures were used in order to compare the final applied strain on the bone graft. In eight experiments (procedure 1), the "Casper type" distracter/compressor was removed and a standard anterior cervical plate with four divergent screws was inserted. In six experiments (procedure 2), a novel plate design was inserted prior to removal of the distracter/compressor, which is not possible with the standard plate design. A final compressive force across the graft was measured. For the standard plate construct (procedure 1), the applied compression force is significantly greater than resting (SO/SC)--P=0.01, but the compression force is not maintained once the compressor is removed (SO/SR)--P=0.27. Final bone graft compression after plate insertion is not significantly different to the resting state (SO/SF)--P=0.16 (Wilcoxon's sign test for paired observation). Application of the plate tended to offload the graft; the final compressive force is 170+/-100% less than the resting force. None of the applied force was maintained (mean 9.5+/-8.8%). For the new plate (procedure 2), the end compressive force (SF) measured across the graft was greater than the resting force (SO) (P<0.001). Further, the novel plate application increased the compressive force on the graft by 712+/-484%. The final bone graft compression using a novel plate, which allows its application prior to removal of the force applicator, is significant (SO/SF)--P=0.01. Here, 77+/-10% of the applied pre-load was maintained. The difference between the plates is significant (P<0.001). Conclusions are as follows: (1) Applied pre-load is not maintained across a graft once the force applicator is removed. (2) Divergent screws with a plate do not compress graft and rather tend to offload it. (3) Compressive force may be maintained if the plate is applied prior to the force applicator removal.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3233962PMC
http://dx.doi.org/10.1007/s00586-005-0054-zDOI Listing

Publication Analysis

Top Keywords

compressive force
32
force
16
cervical spine
12
force maintained
12
divergent screws
12
bone graft
12
graft
10
graft compression
8
adult cervical
8
graft inserted
8

Similar Publications

Objective: Reverse obliquity intertrochanteric fracture is an unstable type of fracture. Current guidelines recommend intramedullary fixation, but there are still complications such as screw removal, hip varus, nail withdrawal, and nail fracture. The objective of this study was to use finite element analysis to compare the biomechanical properties of the novel proximal femoral bionic nail (PFBN), proximal femoral nail antirotation (PFNA), and combined compression interlocking intramedullary nail (InterTan) in the treatment of reverse obliquity intertrochanteric fractures (AO/OTA 31-A3.

View Article and Find Full Text PDF

Orthopedic screws are widely used to achieve bone reduction, compression, and construct stability. However, the relationship between insertion torque, interfragmentary compression, and fixation strength, especially when comparing standard screws with NiTiNOL/sustained dynamic compression (SDC), has not been thoroughly investigated. This study measured insertion torque, interfragmentary compression, and fixation strength for two types of headed orthopedic devices-standard and SDC-using solid foam bone replicates and cadaver validation.

View Article and Find Full Text PDF

Rigid reinforced concrete (RC) frames are generally adopted as stiff elements to make the building structures resistant to seismic forces. However, a method has yet to be fully sought to provide earthquake resistance through optimizing beam and column performance in a rigid frame. Due to its high corrosion resistance, the integration of CFRP offers an opportunity to reduce frequent repairs and increase durability.

View Article and Find Full Text PDF

: This study aimed to establish a predictive model for critical quality attributes (CQAs) related to tablet integrity, including tablet breaking force (TBF), friability, and capping occurrence, using machine learning-based models and nondestructive experimental data. : The machine learning-based models were trained on data to predict the CQAs of metformin HCl (MF)-containing tablets using a commercial-scale wet granulation process, and five models were each compared for regression and classification. We identified eight input variables associated with the process and material parameters that control the tableting outcome using feature importance analysis.

View Article and Find Full Text PDF

Mechanoluminescent (ML) materials emit light by trapping and releasing charge carriers under mechanical stress. However, previous studies do not fully reveal the relationship between emitting light intensity and mechanical stress, thereby affecting the accuracy of stress measurement. This study addresses this gap by systematically investigating ML cylinders with various sizes and loading paths using theoretical analysis and simulations, focusing on the maximum contact stress, equivalent stress distribution, and the relationship between the strain energy density and light intensity at the point of maximum contact stress.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!