Objectives: In this study, quantification of backscatter doses between scattering titanium dental implant and the thermoluminescent dosimeter (TLD(100)) radiation detector at axial beam irradiation-angle range of 0-90 degrees in head and neck radiotherapy is done to evaluate irradiation angle dependency of dose enhancement contributing to osteoradionecrosis.

Methods: A cylindrical titanium dental implant with diameter of 4 mm and length of 9 mm was implanted into a specially-designed human mandible phantom with a TLD100 chip placed on the buccal site and irradiated with 6 MV X, 25 MV X and Co-60 gamma sources at 19 different irradiation angles.

Results: Dose enhancement on a buccal site of the titanium implant depends on the incident beam angle. At angles of 65 degrees, 60 degrees and 40 degrees the maximum detected scatter doses over the titanium implant are 36%, 32% and 23% for Co-60 gamma, 6 MV X-ray and 25 MV X-ray, respectively. The dose enhancement at different beam angles was less pronounced in 25 MV X and more pronounced in Co-60 gamma irradiation.

Conclusions: For the different radiation beams studied, the irradiation angle between scattering titanium dental implants and the central axis does not significantly affect the total dose that may lead to osteoradionecrosis of the mandible.

Download full-text PDF

Source
http://dx.doi.org/10.1259/dmfr/28125805DOI Listing

Publication Analysis

Top Keywords

titanium dental
12
dose enhancement
12
co-60 gamma
12
head neck
8
neck radiotherapy
8
scattering titanium
8
dental implant
8
irradiation angle
8
buccal site
8
titanium implant
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!