Purpose: To describe the outcome of the use of fibrin adhesive (Quixil) in penetrating trabeculectomy in a rabbit model.
Methods: Fibrin adhesive was used experimentally to attach the conjunctiva and the scleral flap in two groups of 17 New Zealand albino adult rabbits (34 eyes). In the first experiment (20 eyes), the fibrin adhesive was used to reattach the tissue after conjunctival peritomy and scleral flap only in 14 eyes (experiment I). In 6 eyes (controls), the conjunctiva was attached with nylon sutures. In the second experiment (14 eyes), the fibrin adhesive was used after conjunctival peritomy, scleral flap, and penetrating trabeculectomy in 8 eyes (experiment II). In a control group of 6 eyes, nylon sutures were used to attach the scleral flap and the conjunctiva after penetrating trabeculectomy. Biomicroscopy and histopathological examinations were performed on postoperative days 1, 3, 7, 14, 21, and 30. Intraocular pressure was measured before and after surgery in the second experiment. Main outcome measures are histological presence of adhesive in the tissue, degree of capillary congestion, inflammatory reaction, collagen density [scar formation] and clinical (IOP measurements before and after surgery, conjunctival chemosis, anterior chamber reaction, presence of filtering bleb and wound leakage).
Results: In experiments I and II, the adhesive was well identified histologically in the tissue as an amorphic eosinophilic substance for up to day 3 and nearly disappeared by day 7. An acute inflammatory reaction was noted for up to 14 days, which converted to chronic inflammation with collagen deposits and scar formation by day 30. Similar inflammatory reaction was observed in the control group. The adhesive had no adverse effects on ocular tissue compared with sutures. One eye in experiment II demonstrated wound dehiscence. Intraocular pressure dropped from 17.35 mmHg preoperatively to 8.28 mmHg on postoperative day 1 in experiment II, and from 17.2 mmHg to 11.5 mmHg in the controls. No significant change in intraocular pressure was noted in experiment I.
Conclusions: The fibrin adhesive had no adverse effects on ocular tissue compared with sutures. It might serve as an effective substitute for conjunctival and scleral wound closure in trabeculectomy surgery.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/02713680500477354 | DOI Listing |
BMJ Case Rep
January 2025
Smt. Kanuri Santhamma Centre for Vitreo Retinal Diseases, Anant Bajaj Retina Institute, LV Prasad Eye Institute, Hyderabad, Telangana, India
A septuagenarian man presented with a visual acuity of hand motions and a large refractory macular hole (MH). We performed an autologous retinal transplant (ART) and covered the graft with fibrin glue without any endotamponade. The autograft was found to have dislocated from the MH when the patient was reviewed 1 week later.
View Article and Find Full Text PDFACS Appl Bio Mater
January 2025
Department of Materials Engineering, Isfahan University of Technology, Isfahan 84156-83111, Iran.
Burns carry a large surface area, varying in shapes and depths, and an elevated risk of infection. Regardless of the underlying etiology, burns pose significant medical challenges and a high mortality rate. Given the limitations of current therapies, tissue-engineering-based treatments for burns are inevitable.
View Article and Find Full Text PDFCells
December 2024
Department of Biochemistry, College of Medicine, Ewha Womans University, Seoul 07804, Republic of Korea.
In general, the nerve cells of the peripheral nervous system regenerate normally within a certain period after the physical damage of their axon. However, when peripheral nerves are transected by trauma or tissue extraction for cancer treatment, spontaneous nerve regeneration cannot occur. Therefore, it is necessary to perform microsurgery to connect the transected nerve directly or insert a nerve conduit to connect it.
View Article and Find Full Text PDFJ Indian Soc Periodontol
December 2024
Department of Periodontology, K. M. Shah Dental College and Hospital, Sumandeep Vidyapeeth, Vadodara, Gujarat, India.
CRSLS
January 2025
Northwell Health-Lenox Hill Hospital, New York, NY. (Drs. Chu, Alden, and Seckin).
Introduction: There is a risk of iatrogenic vascular injuries during robotic-assisted laparoscopic excision of diaphragmatic endometriosis. Although studies are limited, the first reported case of a suprahepatic inferior vena cava (IVC) injury during robotic diaphragmatic endometriosis excision was successfully treated using a fibrin sealant patch, preventing exsanguination and conversion to laparotomy.
Case Description: A 36-year-old female with a history of recurrent catamenial pneumothorax and two prior video-assisted thoracoscopic surgeries to treat diaphragmatic endometriosis presented to our clinic with right-sided shoulder pain and a chest tube in place.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!