Conventionally, large-mode-area (LMA) fiber lasers use free-space polarizing components to achieve linear polarization output. External components, however, significantly limit laser robustness and power scalability. We demonstrate, to the best of our knowledge, the first high-power all-fiber cavity single-polarization single-transverse-mode LMA fiber laser, without the use of free-space polarizing components. This has been achieved by using tightly coiled high-birefringence 20 microm core LMA fiber. The lasing spectrum at 1085 nm has been stabilized by a fiber grating, spliced at one end of a LMA fiber. Up to 405 W of single-polarization output with a polarization extinction of >19 dB with a narrow spectrum (1.9 nm FWHM) and in a single-transverse mode (M2 < 1.1) has been demonstrated. The simplicity of a monolithic-cavity approach is highly beneficial for a number of applications, including the use of a fiber laser for nonlinear wavelength conversion and for coherent and spectral beam combining.

Download full-text PDF

Source
http://dx.doi.org/10.1364/ol.31.000017DOI Listing

Publication Analysis

Top Keywords

lma fiber
16
fiber laser
12
single-polarization single-transverse-mode
8
all-fiber cavity
8
free-space polarizing
8
polarizing components
8
fiber
7
high-power single-polarization
4
single-transverse-mode fiber
4
laser
4

Similar Publications

Article Synopsis
  • High-power tunable lasers are highly sought after for their applications in telecom, ranging, and molecular sensing, but integrated photonics has struggled with power due to size limitations.
  • The introduction of large-mode-area (LMA) fibers in the late 90s significantly improved the power capability of fiber systems by increasing the optical mode area.
  • This study demonstrates a silicon photonics-based LMA power amplifier that achieves an output power of 1.8W over a 60nm tunability range, indicating a potential advancement in integrated lasers for high-power applications that can compete with traditional bench systems.
View Article and Find Full Text PDF

Background: The Laryngeal Mask Airway Vision Mask (LMA VM) is a supraglottic airway device (SAD) with a vision guidance system. The ideal head and neck position for direct laryngoscopy is known, but the ideal position for placing a LMA is not. The objective of this study is to evaluate and compare the optimal position for placement of a video laryngeal mask airway.

View Article and Find Full Text PDF

Perforated imprinting on high moisture meat analogue confers long range mechanical anisotropy resembling meat cuts.

NPJ Sci Food

December 2024

Department of Physiology, The Institute for Digital Medicine (WisDM), Yong Loo Lin School of Medicine, National University of Singapore, Singapore, 117593, Singapore.

Meat cuts, when cooked and masticated, separate into fibrous structures because of the long-range mechanical anisotropy (LMA) exhibited by muscle fascicles, which is not fully recapitulated in alternative proteins produced using molecular alignment technology like high moisture extrusion. We have developed a scalable perforated micro-imprinting technology to greatly enhance LMA in high moisture meat analogue (HMMA). By imprinting 1 mm thick HMMA sheets with perforated patterns (optimized by AI), we observed up to 5 × more anisotropic separation of fibrous structures in a one-dimensional pulling LMA analysis, to match the fibrousness of the cooked chicken breast, duck breast, pork loin and beef loin.

View Article and Find Full Text PDF

High-power Tm-doped fiber lasers operating at short wavelengths (< 1940 nm) are widely used in biomedical engineering, remote sensing, and pumping Ho-doped solid-state lasers. However, it is challenging to increase their output power. Amplified spontaneous emission (ASE) is a major bottleneck in scaling the power of Tm-doped fiber lasers operating at short wavelengths.

View Article and Find Full Text PDF
Article Synopsis
  • The study compares two methods for inserting a laryngeal mask airway (LMA): the standard technique and a technique using a 30° curved tongue depressor.
  • Involving 154 patients, the results showed a significantly higher first-attempt success rate for the tongue depressor-aided method (97.40%) compared to the standard method (88.31%).
  • Additionally, the tongue depressor technique reduced the incidence of sore throat symptoms post-insertion, suggesting it as a superior option for LMA insertion.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!