Purpose: To compare Mersilene mesh versus sclera in wrapping hydroxyapatite orbital implants used in primary enucleation.

Methods: In a prospective, randomized, interventional comparative case series, 60 eyes from 60 consecutive patients were included and randomly allocated for primary enucleation and either Mersilene mesh-wrapped hydroxyapatite (MHA) orbital implant (30 cases, 50%) or sclera-wrapped hydroxyapatite (SHA) orbital implant (30 cases, 50%) under general anesthesia. Complete socket examination was performed at 1 week, 1 month, and then every 3 months after surgery.

Results: Mean age was not significantly different (P = 0.08) between patients with MHA (36.43 years) and SHA (28.50 years) orbital implants. The most common cause of enucleation was trauma in both groups (P = 0.09). Patients with MHA had significantly (P = 0.005) longer follow-up time (mean, 11.40 months) than those with SHA (mean, 9.40 months). No exposure was found at last follow-up in the MHA group, but one patient in the SHA group had a small exposure (1 x 1 mm) 1 month after surgery that was conservatively treated. There were no significant postoperative soft tissue complications in either group.

Conclusions: Sclera and Mersilene mesh could be used as a wrapping material for hydroxyapatite orbital implants without significant complications. Absence of disease transmission, low cost, and availability are the main advantages of Mersilene mesh.

Download full-text PDF

Source
http://dx.doi.org/10.1097/01.iop.0000192633.86564.beDOI Listing

Publication Analysis

Top Keywords

mersilene mesh
16
orbital implants
16
hydroxyapatite orbital
12
mesh versus
8
versus sclera
8
sclera wrapping
8
wrapping hydroxyapatite
8
orbital implant
8
implant cases
8
cases 50%
8

Similar Publications

Novel antimicrobial coating for hernia meshes.

Front Cell Infect Microbiol

November 2024

Department of Orthopaedic Surgery, Universitätsklinikum Gießen und Marburg (UKGM), Justus-Liebig-University, Gießen, Germany.

Purpose: Antibiotic coating for several medical devices has been carried out; however, there are only few studies about coating hernia meshes with antimicrobial substances. In this study we checked the capacity of different commercially available hernia meshes to act as drug carrier.

Methods: The meshes were coated with gentamicin palmitate, chlorhexidine palmitic acid and chlorhexidine palmitate.

View Article and Find Full Text PDF

Patches in Congenital Diaphragmatic Hernia: Systematic Review.

Ann Surg

August 2024

Department of Paediatric Surgery, Chelsea and Westminster Hospital NHS Foundation Trust, Imperial College London, London, UK.

Objective: This systematic review aims to evaluate current choices in practice and outcomes of biomaterials used in patch repair of congenital diaphragmatic hernia (CDH).

Background: Multiple biomaterials, both novel and combinations of pre-existing materials are employed in patch repair of large size CDHs.

Methods: A literature search was performed across Embase, Medline, Scopus, and Web of Science.

View Article and Find Full Text PDF

Introduction And Importance: Mediastinal teratoma is the most common mediastinal germ cell tumor. Mature mediastinal teratomas are infrequent and often found incidentally.

Case Presentation: We report the case of a 14-year-old girl who was presented dyspnea for 2 years.

View Article and Find Full Text PDF

Modified Oxford technique of colpopexy for the treatment of uterine and vaginal vault prolapse: a retrospective pilot cohort study.

Front Surg

June 2023

Clinic of Gynecology, Obstetrics and Gynecological Oncology, University Hospital for Gynecology, Pius-Hospital Oldenburg, Medical Campus University of Oldenburg, Oldenburg, Germany.

Introduction: Pelvic organ prolapse is a common health issue that affects 30.8% of women. Laparoscopic sacrocolpopexy and colpopectopexy are two of the most common procedures to restore the pelvic anatomy.

View Article and Find Full Text PDF

Ankylosis of the temporomandibular joint (TMJ) is one of the most prevalent TMJ disorders in patients who have experienced trauma. Due to the high risk of recurrence, gap arthroplasty without interpositional material has been gradually discontinued as a treatment for TMJ ankylosis. After arthroplasty surgery, various interposition materials have been used to prevent a recurrence.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!