Objective: To observe the tested results of the segmental range of motion (ROM) of lumbar spine by charge couple device (CCD)-based system for 3-dimensional real-time positioning (CCD system), and to analyze its clinical significance.
Methods: Seven patients with lumbar joint dysfunction and 8 healthy subjects were tested twice by the CCD-based system with an interval of 10 min.
Results: The ROM of the patients was obviously lesser than that of the healthy subjects. The measuring data of segmental ROM of lumbar spine by CCD system is correlated significantly to the same data checked later on the same subjects in every direction of the movements. The differences between two checks are usually less than 1 degree.
Conclusion: Specially designed CCD based system for 3-dimensional real-time positioning could objectively reflect the segmental ROM of lumbar spine. The system would be of great clinical significance in the assessment of the biomechanical dysfunction of lumbar spine and the effect of the treatment applied.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/BF02835788 | DOI Listing |
Eur Spine J
January 2025
Department of Orthopedics, the Seventh Affiliated Hospital, Sun Yat-sen University, Shenzhen, 518000, Guangdong, China.
Objectives: Sleep disorders are considered a risk factor for aging and skeletal degeneration, but their impact on intervertebral disc degeneration (IDD) remains unclear. The aim of this study was to assess associations between sleep characteristics and IDD, and to identify potential causal relationships.
Methods: Exposure factors included six unhealthy sleep characteristics: insomnia, short sleep duration (< 7 h), long sleep duration (≥ 9 h), evening chronotype, daytime sleepiness, and snoring.
Global Spine J
January 2025
Research & Development, Endospine SLU, Andorra la Vella, Andorra.
Study Design: Exploratory prospective observational case-control study.
Objectives: Aim of this study was to compare clinical and radiologic outcome, as well as peri-operative complications, of anterior lumbar interbody fusion (ALIF) and full-endoscopic/percutaneous trans-Kambin transforaminal lumbar interbody fusion (pTLIF) with a large-footprint interbody cage.
Methods: Patients that underwent elective ALIF and pTLIF with a large-footprint interbody cage were prospectively evaluated.
Life Sci Space Res (Amst)
February 2025
Department of Biomedical Engineering, Center for Injury Biomechanics, Wake Forest University School of Medicine. 575 N. Patterson Avenue, Suite 530. Winston-Salem, NC 27101, USA. Electronic address:
Muscle atrophy occurs with extended exposure to microgravity. This study quantified the overall muscle size, lean muscle area and fat infiltration changes pre- to post-flight that occur in the thoracic and lumbar spine with long-duration spaceflight. Pre- and post-flight magnetic resonance imaging (MRI) scans were obtained from 9 crewmembers on long-duration (≥6 months) International Space Station (ISS) missions.
View Article and Find Full Text PDFBone Joint Res
January 2025
Department of Anatomy and Anthropology, School of Medicine, Faculty of Medical and Health Sciences, Tel Aviv University, Tel Aviv, Israel.
Aims: The development of lumbar lordosis has been traditionally examined using angular measurements of the spine to reflect its shape. While studies agree regarding the increase in the angles during growth, the growth rate is understudied, and sexual dimorphism is debated. In this study, we used a novel method to estimate the shape of the lumbar curve (LC) using the landmark-based geometric morphometric method to explore changes in LC during growth, examine the effect of size and sex on LC shape, and examine the associations between angular measurements and shape.
View Article and Find Full Text PDFIntroduction: Zinc, an essential trace element, plays an important role in various cellular processes, and zinc deficiency is common in patients undergoing hemodialysis. Zinc has been shown to stimulate osteoblastic bone formation and mineralization and inhibit osteoclastic bone resorption. Although osteoporosis is highly prevalent among patients undergoing hemodialysis, the utility of areal bone mineral density (aBMD) measured using dual-energy X-ray absorptiometry (DXA) is limited because DXA cannot reveal bone microarchitectural alterations.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!