A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Clamping of the dialysate outlet line in the Genius dialysis system does not alter dialysate flow or clearances. | LitMetric

Background: The Genius dialysis system is advocated as a tool to perform slow extended daily dialysis (SLEDD) in patients with acute renal failure at the intensive care unit. At low blood flows however, it is sometimes problematic to maintain sufficient systemic pressure in the dialysate circuit, a problem that can be overcome by clamping the dialysate outflow line. This intervention can however decrease the flow in the dialysate circuit, and can thus potentially decrease the clearance. This article analyses the impact of this intervention on the blood and dialysate flows and on the removal of retention products.

Methods: The study was done in 20 stable chronic dialysis patients to avoid additional bias caused by changing comorbidities in ICU patients. Patients were treated by Genius, once with clamping and once without clamping, cross-over in a randomized fashion, and with 1 week interval. Flows in the dialysate and blood circuit were measured with a transsonic flow probe. Urea, creatinine, Beta 2 microglobulin and phosphate were measured in the dialysate, and in the serum before and after dialysis.

Results: There was no clinically significant difference in blood or dialysate flows, nor in clearance or removal of retention products during the sessions with or without clamping.

Conclusions: The technique of using clamping of the dialysate outflow line in the Genius system to increase systemic pressure, when the system is used in SLEDD, is a safe technique which does not alter the clearances.

Download full-text PDF

Source
http://dx.doi.org/10.1093/ndt/gfk038DOI Listing

Publication Analysis

Top Keywords

clamping dialysate
12
dialysate
9
genius dialysis
8
dialysis system
8
systemic pressure
8
dialysate circuit
8
dialysate outflow
8
blood dialysate
8
dialysate flows
8
removal retention
8