We consider the task of detecting a statistically varying signal of known location on a statistically varying background in a reconstructed tomographic image. We analyze the performance of linear observer models in this task. We show that, if one chooses a suitable reconstruction method, a broad family of linear observers can exactly achieve the optimal detection performance attainable with any combination of a linear observer and linear reconstructor. This conclusion encompasses several well-known observer models from the literature, including models with a frequency-selective channel mechanism and certain types of internal noise. Interestingly, the "optimal" reconstruction methods are unregularized and in some cases quite unconventional. These results suggest that, for the purposes of designing regularized reconstruction methods that optimize lesion detectability, known-location tasks are of limited use.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TMI.2005.859714DOI Listing

Publication Analysis

Top Keywords

known-location tasks
8
tomographic image
8
statistically varying
8
linear observer
8
observer models
8
reconstruction methods
8
analysis observer
4
observer performance
4
performance known-location
4
tasks tomographic
4

Similar Publications

Objective: The present study was designed to examine the impact that walking has on performance in auditory localization, visual discrimination, and aurally aided visual search tasks.

Background: Auditory localization and visual search are critical skills that are frequently conducted by moving observers, but most laboratory studies of these tasks have been conducted on stationary listeners who were either seated or standing during stimulus presentation.

Method: Thirty participants completed three different tasks while either standing still or while walking at a comfortable self-selected pace on a treadmill: (1) an auditory localization task, where they identified the perceived location of a target sound; (2) a visual discrimination task, where they identified a visual target presented at a known location directly in front of the listener; and (3) an aurally aided visual search task, where they identified a visual target that was presented in the presence of multiple visual distracters either in isolation or in conjunction with a spatially colocated auditory cue.

View Article and Find Full Text PDF

Does visual working memory represent the predicted locations of future target objects? An event-related brain potential study.

Brain Res

November 2015

Department of Psychological Sciences, Birkbeck College, University of London, Malet Street, London WC1E 7HX, UK. Electronic address:

During the maintenance of task-relevant objects in visual working memory, the contralateral delay activity (CDA) is elicited over the hemisphere opposite to the visual field where these objects are presented. The presence of this lateralised CDA component demonstrates the existence of position-dependent object representations in working memory. We employed a change detection task to investigate whether the represented object locations in visual working memory are shifted in preparation for the known location of upcoming comparison stimuli.

View Article and Find Full Text PDF

Task-based assessments of image quality constitute a rigorous, principled approach to the evaluation of imaging system performance. To conduct such assessments, it has been recognized that mathematical model observers are very useful, particularly for purposes of imaging system development and optimization. One type of model observer that has been widely applied in the medical imaging community is the channelized Hotelling observer (CHO), which is well-suited to known-location discrimination tasks.

View Article and Find Full Text PDF

Purpose: A number of different techniques have been developed to reduce radiation dose in x-ray computed tomography (CT) imaging. In this paper, the authors will compare task-based measures of image quality of CT images reconstructed by two algorithms: conventional filtered back projection (FBP), and a new iterative reconstruction algorithm (IR).

Methods: To assess image quality, the authors used the performance of a channelized Hotelling observer acting on reconstructed image slices.

View Article and Find Full Text PDF

Optimization of computed tomography protocols: limitations of a methodology employing a phantom with location-known opacities.

J Digit Imaging

December 2013

Medical Image Optimisation and Perception Group (MIOPeG), Medical Imaging & Radiation Sciences Faculty Research Group, Faculty of Health Sciences, The University of Sydney, Cumberland Campus, Lidcombe, NSW, 2141, Australia,

This study aimed to determine if phantom-based methodologies for optimization of hepatic lesion detection with computed tomography (CT) require randomization of lesion placement and inclusion of normal images. A phantom containing fixed opacities of varying size (diameters, 2.4, 4.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!