Rapid detection of micro-organisms from blood is one of the most critical functions of a diagnostic microbiology laboratory. Automated blood-culture systems reduce the time needed to detect positive cultures, and reduce specimen handling. The false-positive rate of such systems is 1-10%. In this study, the presence of pathogens in 'false-positive' bottles obtained from BACTEC 9050 (Becton Dickinson) and BacT/Alert (Biomérieux) systems was investigated by eubacterial and fungal PCR. A total of 169 subculture-negative aerobic blood-culture bottles (104 BacT/Alert and 65 BACTEC) were evaluated. Both fungal and eubacterial PCRs were negative for all BACTEC bottles. Fungal PCR was also negative for the BacT/Alert system, but 10 bottles (9.6%) gave positive results by eubacterial PCR. Sequence analysis of the positive PCR amplicons indicated the presence of the following bacteria (number of isolates in parentheses): Pasteurella multocida (1), Staphylococcus epidermidis (2), Staphylococcus hominis (1), Micrococcus sp. (1), Streptococcus pneumoniae (1), Corynebacterium spp. (2), Brachibacterium sp. (1) and Arthrobacter/Rothia sp. (1). Antibiotic usage by the patients may be responsible for the inability of the laboratory to grow these bacteria on subcultures. For patients with more than one false-positive bottle, molecular methods can be used to evaluate the microbial DNA in these bottles. False positives from the BACTEC system may be due to elevated patient leukocyte counts or the high sensitivity of the system to background increases in CO(2) concentration.

Download full-text PDF

Source
http://dx.doi.org/10.1099/jmm.0.46196-0DOI Listing

Publication Analysis

Top Keywords

automated blood-culture
8
blood-culture systems
8
fungal pcr
8
pcr
5
bottles
5
pcr evaluation
4
evaluation false-positive
4
false-positive signals
4
signals automated
4
systems
4

Similar Publications

Background: Carbapenem-resistant Klebsiella pneumoniae (CRKP) is a difficult to treat organism owing to limited therapeutic options. So far, little is known about the molecular characteristics of CRKP in Palestine.

Objectives: The aim of this study was to investigate the antimicrobial resistance patterns, multilocus sequence types (ST) and resistance genes among clinical K.

View Article and Find Full Text PDF

Background: Reports of cases of bacterial infection due to transfusion of red blood cell (RBC) components (RBC-TTBI) are relatively rare. Hence, the possibility of undetectable bacterial contamination in RBCs, especially by psychrotrophic bacteria, must be clarified.

Study Design And Methods: We assessed nine psychrotrophic bacterial species, including those implicated in bacteremia or RBC-TTBIs.

View Article and Find Full Text PDF

We aimed to investigate the diagnostic value of leukocyte cell population data (CPD) parameters obtained from an automated hematology analyzer to be able to use it in the diagnosis of neonatal sepsis. Our study was a retrospective and cross-sectional analysis. The neonates were classified into 3 groups: culture-positive sepsis (n = 20), clinical sepsis (n = 87), and control (n = 269).

View Article and Find Full Text PDF
Article Synopsis
  • Invasive candidiasis (IC) is a major concern in hospitals, often difficult to diagnose due to limitations in blood culture methods.
  • A study evaluated the effectiveness of the FungiXpert® BDG Detection Kit for diagnosing IC, showing it had a sensitivity of 60.52% and specificity of 81.81% among 80 patients tested.
  • Results indicated that higher BDG levels correlated with more severe outcomes, suggesting the kit could be useful for diagnosis, especially in resource-limited settings.
View Article and Find Full Text PDF

Evaluation of Zhuhai DL Biotech's BT24 automated blood culture system.

Enferm Infecc Microbiol Clin (Engl Ed)

December 2024

Servicio de Microbiología, Hospital Universitario de Getafe, Getafe, Madrid, Spain. Electronic address:

Introduction: For the microbiological diagnosis of bacteremia and fungemia, it is essential to use automated blood culture systems that guarantee good performance in the detection of microorganisms. We evaluated the BT24 system for blood cultures by comparing it with the BACTEC™ FX system in detection of positive spiked blood cultures (BC) and bottles, subsequent growth of the microorganism, and time to detection (TTD).

Methods: The parallel analysis of both systems was performed with 160 strains of 31 different species, each inoculated under the same conditions and simultaneously in six blood culture bottles.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!