A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Imaging and quantification of myocardial perfusion using real-time three-dimensional echocardiography. | LitMetric

Objectives: We tested the feasibility of real-time three-dimensional echocardiographic (RT3DE) perfusion imaging and developed and validated an algorithm for volumetric analysis of myocardial contrast inflow. The study included three protocols wherein perfusion was measured: 1) in an ex-vivo model of controlled global coronary flow, 2) in an in-vivo model during regional perfusion variations, and 3) in humans during pharmacologically induced hyperemia.

Background: The RT3DE technology offers an opportunity for myocardial perfusion imaging without multi-slice reconstruction and repeated contrast maneuvers.

Methods: Electrocardiographically triggered harmonic RT3DE datasets were acquired (Philips 7500) while infusion of Definity was initiated and reached a steady state. Protocol 1 was performed in nine isolated rabbit hearts and included three coronary flow levels. In protocol 2, changes in regional perfusion caused by partial left anterior descending artery occlusion were measured in five pigs. In protocol 3, adenosine-induced changes in perfusion were measured in eight normal volunteers. Myocardial video-intensity (MVI) was measured over time in three-dimensional (3D) slices to calculate peak contrast inflow rate (PCIR). In pigs, PCIR was measured on a regional basis and validated against microspheres.

Results: The RT3DE imaging allowed selection of slices for perfusion analysis in rabbit hearts, pigs, and humans. Administration of contrast resulted in clearly visible and quantifiable changes in MVI. In rabbits, The PCIR progressively decreased with coronary flow (p < 0.0001). In pigs, coronary occlusion caused a 59 +/- 26% decrease in PCIR exclusively in the left anterior descending artery territory (p < 0.05) in agreement with microspheres. In humans, adenosine increased PCIR to 198 +/- 57% of baseline (p < 0.05).

Conclusions: Contrast-enhanced RT3DE imaging provides the basis for volumetric imaging and quantification of myocardial perfusion.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jacc.2005.08.053DOI Listing

Publication Analysis

Top Keywords

myocardial perfusion
12
coronary flow
12
perfusion
9
imaging quantification
8
quantification myocardial
8
real-time three-dimensional
8
perfusion imaging
8
contrast inflow
8
included three
8
perfusion measured
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!