A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Analysis of neovascularization of PEGT/PBT-copolymer dermis substitutes in balb/c-mice. | LitMetric

Analysis of neovascularization of PEGT/PBT-copolymer dermis substitutes in balb/c-mice.

Burns

Department of Plastic and Hand Surgery, Burn Center, Department of Pathology, University Hospital Bergmannsheil, Ruhr University Bochum, Buerkle-de-la-Camp Platz 1, 44789 Bochum, Germany.

Published: February 2006

Introduction: A fundamental prerequisite for using degradable synthetic biopolymers as composite skin substitutes is the ability to establish vascular tissue. PEGT/PBT block-copolymer matrices have previously been shown as a favorable dermal substitute. In this study, quantitative data on neovascularization of PEGT/PBT block-copolymer matrices are presented.

Materials And Methods: PEGT/PBT-block-copolymer discs of three different pore diameters (1: < 75 microm, 2: 75-212 microm, 3: 250-300 microm) were implanted into dorsal skinfold chambers of balb/c mice. Histological sections were evaluated 7, 14, and 21 days post implantation by light and scanning electron microscopy. Blood vessel analysis was performed by means of digital image analysis (n = 288) of hematoxylin/eosin stained sections within apical (AOF) and basal (BOF) observation fields of the matrices.

Results: Twenty-one days after implantation the density of blood vessels within the BOF of the scaffolds with a pore size of 75-212 and 250-300 microm were 4.6 +/- 0.45 and 5.8 +/- 0.62 (mean +/- S.E.M.; blood vessel profiles (BVF)), respectively. In <75 microm scaffolds, smaller numbers of BVF were found (4.2 +/- 0.39). In contrast, the evaluation within the AOF revealed significantly higher numbers of BVF in 75-212 microm group (3.5 +/- 0.49) and 250-300 microm group (4.5 +/- 0.66) as compared to the < 75 microm group (2.3 +/- 0.48).

Conclusion: There is evidence that the three-dimensional structure of PEGT/PBT-block-copolymer (pore size structure) influences neovascularization. The porous structures of copolymer matrices with adequate interconnection of pores (pore sizes of 75-212 and 250-300 microm) are characterized by faster ingrowth of vascular tissue.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.burns.2005.07.009DOI Listing

Publication Analysis

Top Keywords

pegt/pbt block-copolymer
8
block-copolymer matrices
8
250-300 microm
8
blood vessel
8
analysis neovascularization
4
neovascularization pegt/pbt-copolymer
4
pegt/pbt-copolymer dermis
4
dermis substitutes
4
substitutes balb/c-mice
4
balb/c-mice introduction
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!